Description: Key/card counter device error 4 After installation of the device a message alerts user to a battery voltage abnormal error.
Causes: • Device control board defective • Device control board backup battery defective
Code: 636
Description: OSM User Code File Error The correct "usercode" file could not be found in the root folder of the SD card because the file is not present, or the existing file is corrupted or the wrong type file.
Causes: • Make sure the eccm.mod file is in the root folder of the SD card. Note: The usercode files are created with the User Setting Tool "IDissuer.exe".
Code: 641
Description: Engine-Controller Communication Error: Non-Response There was no response to a frame sent from the controller board to the engine.
Causes: • Turn the machine power off/ on.
Code: 650
Description: Communication error of the remote service modem (Cumin-M)
Causes: -001 - Authentication error The authentication for the Cumin-M failed at dial up connection. • Incorrect SP settings • Disconnected telephone line • Disconnected modem board Check and set the correct user name (SP5816-156) and password (SP5816-157). -004 - Incorrect modem setting Dial up fails due to the incorrect modem setting. Same as -001 -005 - Communication line error The supplied voltage is not sufficient due to the defective communication line or defective connection. Same as -001 Consult with the user's local telephone company. -011 - Incorrect network setting Both the NIC and Cumin-M are activated at the same time. Same as -001 Disable the NIC with SP5985-1. -012 - Modem board error The modem board does not work properly even though the setting of the modem board is installed with a dial up connection. Same as -001 Install the modem board. Check and reset the modem board setting with SP5816. Replace the modem board.
Code: 651
Description: Incorrect dial up connection
Causes: -001: Program parameter error -002: Program execution error An unexpected error occurred when the modem (Cumin-M) tried to call the center with a dial up connection. • Caused by a software bug • No action required because this SC does not interfere with operation of the machine.
Code: 669
Description: EEPROM Communication Error The machine failed to detect a match between the read/write data for the EEPROM on the BCU after 3 attempts.
Causes: • EEPROM installed incorrectly • EEPROM defective. Turn the machine power off/on after replacing the EEPROM. • BCU defective.
Code: 670
Description: Engine response error After powering on the machine, a response is not received from the engine within 30 seconds.
Description: Controller-to-operation panel communication error at startup After powering on the machine, the communication circuit between the controller and the operation panel is not opened, or communication with controller is interrupted after a normal startup.