Các lỗi thường gặp

Code :
  • Code: 650-012
  • Description: Communication error of the remote service modem (Embedded RCG-M): Modem board error
    The modem board does not work properly even though the setting of the modem board is installed with a dial up connection.
  • Causes: • Same as -001 1. Install the modem board. 2. Check and reset the modem board setting with SP5816. 3. Replace the modem board.
  • Code: 651-001
  • Description: Incorrect dial up connection: Program parameter error
    An unexpected error occurs when the modem (Embedded RCG-M) tries to call the center with a dial up connection.
  • Causes: • Caused by a software bug
  • Code: 651-002
  • Description: Incorrect dial up connection: Program execution error
    An unexpected error occurs when the modem (Embedded RCG-M) tries to call the center with a dial up connection.
  • Causes: • Caused by a software bug
  • Code: 669
  • Description: EEPROM error
    Retry of EEPROM communication fails three times after the machine has detected the EEPROM error.
  • Causes: • Caused by noise
  • Code: 670
  • Description: Engine startup error
    The BICU fails to respond with the prescribed time when the machine is turned on.
  • Causes: • Connections between BICU and controller board are loose, disconnected, or damaged 1. Replace the BICU 2. Replace the controller board
  • Code: 671
  • Description: BICU error
    The model code from the BICU is not correct when the machine is turned on.
  • Causes: Install the correct BICU for this model.
  • Code: 672
  • Description: Controller-to-operation panel communication error at startup
    • After the machine is powered on, the communication between the controller and the operation panel is not established, or communication with controller is interrupted after a normal startup. • After startup reset of the operation panel, the attention code or the attention acknowledge code is not sent from the controller within 15 seconds. • After the controller issues a command to check the communication line with the controller at 30-second intervals, the controller fails to respond twice.
  • Causes: • Controller stalled • Controller board installed incorrectly • Controller board defective • Operation panel connector loose or defective • The controller is not completely shutdown when you turn the main switch off. Check the setting of SP5875-001. If the setting is set to "1 (OFF)", change it to "0 (ON)".
  • Code: 687
  • Description: Memory address (PER) command error
    The BICU does not receive a memory address command from the controller for the prescribed time after the paper has reached the registration sensor.
  • Causes: • Harness Disconnection at BICU • Controller board loose or broken • Defective BICU • Defective Controller Board