Các lỗi thường gặp

Code :
  • Code: SC202-00
  • Description: Polygon Motor: ON Timeout Error After the polygon motor turned on, or within T1 sec. after the rpm’s changed, the motor did not enter READY status.
  • Causes: • The interface harness to the polygon motor driver damaged or not connected correctly. • Polygon motor or polygon motor driver defective • Polygon motor drive pulse cannot be output correctly. (Polygon controller) • XSCRDY signal observation failing (Polygon controller)
  • Remedy: • Turn the power off/on • Replace the laser unit or polygon motor • Replace the polygon harness • Replace the IPU board
  • Code: SC203-00
  • Description: Polygon Motor: OFF Timeout Error The XSCRDY signal (polygon ready) never becomes inactive (H) within 3 sec. after the polygon motor went OFF.
  • Causes: • The interface harness to the polygon motor driver damaged or not connected correctly. • Polygon motor or polygon motor driver defective • Polygon motor drive pulse cannot be output correctly. (Polygon controller) • XSCRDY signal observation failing (Polygon controller)
  • Remedy: • Turn the power off/on • Replace the laser unit or polygon motor • Replace the polygon harness • Replace the IPU board
  • Code: SC204-00
  • Description: Polygon Motor: XSCRDY Signal Error During polygon motor rotation, the XSCRDY signal was inactive (H) for longer than one rotation of the polygon.
  • Causes: • The interface harness to the polygon motor driver damaged or not connected correctly. • Polygon motor or polygon motor driver defective
  • Remedy: • Turn the power off/on • Replace the laser unit or polygon motor • Replace the polygon harness • Replace the IPU board
  • Code: SC220-00
  • Description: Laser synchronization detection error: LD0 The laser synchronizing detection signal for the start position of the LD was not output for 500 msec. after LDB unit turned on with the polygon motor rotating normally.
  • Causes: • The interface harness to the synchronization detection unit damaged or not connected correctly. • Synchronization detection board defective • Beam does not enter photo detector. • Abnormality around GAVD • IDB (LED driver) defective • LDB defective • IPU defective
  • Remedy: • Turn the power off/on • Replace the laser unit or polygon motor • Replace the polygon harness • Replace the IPU board
  • Code: SC230-00
  • Description: FGATE ON error The FGATE signal did not turn ON within 1 sec. after the writing process started.
  • Causes: • GAVD defective • Image processing ASIC defective • IPU, controller board not connected correctly or defective • Harness between IPU and LDB defective
  • Remedy: • Turn the power off/on • Replace the IPU board • Replace the controller board
  • Code: SC231-00
  • Description: FGATE OFF error The FGATE signal did not turn OFF within 9 sec. after the writing procesended.
  • Causes: • GAVD defective • Image processing ASIC defective • IPU, controller board not connected correctly or defective • Harness between IPU and LDB defective
  • Remedy: • Turn the power off/on. • Replace the IPU board. • Replace the controller board.
  • Code: SC240-00
  • Description: LD error: During LD lighting /During initialization of P-MAC
  • Causes: • LD degradation (LD broken, shift of output characteristics etc.) • The interface harness damaged or not connected correctly. • LD driver defective
  • Remedy: • Cycle the main power off/on • Replace the LD unit • Replace the harness • Replace the IPU board
  • Code: SC270-00
  • Description: GAVD communication error When machine starts or cancels the energy saving
  • Causes: • GAVD defective • CPU defective • BCU defective
  • Remedy: • Cycle the main power off/on • Replace the IPU board • Replace the controller board • Replace the BCU board • Set the FCC between BCU - IPU