Description: Polygon Motor: ON Timeout Error After the polygon motor turned on, or within T1 sec. after the rpm’s changed, the motor did not enter READY status.
Causes: • The interface harness to the polygon motor driver damaged or not connected correctly. • Polygon motor or polygon motor driver defective • Polygon motor drive pulse cannot be output correctly. (Polygon controller) • XSCRDY signal observation failing (Polygon controller)
Remedy: • Turn the power off/on • Replace the laser unit or polygon motor • Replace the polygon harness • Replace the IPU board
Description: Polygon Motor: OFF Timeout Error The XSCRDY signal (polygon ready) never becomes inactive (H) within 3 sec. after the polygon motor went OFF.
Causes: • The interface harness to the polygon motor driver damaged or not connected correctly. • Polygon motor or polygon motor driver defective • Polygon motor drive pulse cannot be output correctly. (Polygon controller) • XSCRDY signal observation failing (Polygon controller)
Remedy: • Turn the power off/on • Replace the laser unit or polygon motor • Replace the polygon harness • Replace the IPU board
Description: Polygon Motor: XSCRDY Signal Error During polygon motor rotation, the XSCRDY signal was inactive (H) for longer than one rotation of the polygon.
Causes: • The interface harness to the polygon motor driver damaged or not connected correctly. • Polygon motor or polygon motor driver defective
Remedy: • Turn the power off/on • Replace the laser unit or polygon motor • Replace the polygon harness • Replace the IPU board
Description: Laser synchronization detection error: LD0 The laser synchronizing detection signal for the start position of the LD was not output for 500 msec. after LDB unit turned on with the polygon motor rotating normally.
Causes: • The interface harness to the synchronization detection unit damaged or not connected correctly. • Synchronization detection board defective • Beam does not enter photo detector. • Abnormality around GAVD • IDB (LED driver) defective • LDB defective • IPU defective
Remedy: • Turn the power off/on • Replace the laser unit or polygon motor • Replace the polygon harness • Replace the IPU board