Code: 555

Description: Fusing lamp consecutive full power 1
After warm-up, the fusing lamp remains at full power for 15 seconds without the hot roller rotating.
Causes: • Disconnected or defective thermistors (ends) • Defective fusing lamp

Code: 557

Description: Zero cross frequency error
When the zero cross signal is 66 or more and it is detected 10 times or more in 11 detections, the machine determines that input 60 Hz and SC557 occurs.
Causes: • Noise (High frequency)

Code: 559

Description: Fusing unit jam
The fusing sensor detected a fusing unit paper late jam three times. The paper was late and the fusing exit sensor could not detect the paper three times.
Causes: • Remove the paper that is stopped in the fusing unit. • Check that the fusing unit is clean and has no obstacles in the paper feed path. • If the error persists, replace the fusing unit.

Code: 610

Description: Mechanical counter error: BK
This SC is only for NA models. The machine detects the mechanical counter error when SP5987-001 is set to "1".
Causes: • Disconnected mechanical counter • Defective mechanical counter

Code: 620-01

Description: ADF communication error: Communication error between machine and ADF
Communication error between machine and ADF with ASAP is detected.
Causes: Disconnected cable
ARDF defective
IPU board defective External noise

Code: 620-02

Description: ADF communication error: Communication error between IPU and ADF
After the ARDF is detected, the break signal occurs or communication timeout occurs.
Causes: Incorrect installation of ARDF
ARDF defective

Code: 621

Description: Communication timeout error between IOB and finisher or mailbox
A break (low) signal is received from the finisher or the mailbox.
Causes: • Disconnected cable • Defective IOB • Defective main board in the peripherals

Code: 622

Description: Paper feed unit communication error
While the IOB communicates with a peripheral, an SC code is displayed if one of following conditions occurs. • The IOB receives the break signal which is generated by the peripheral only just after the main switch is turned on. • The IOB receives the break signal which is generated by URAT.
Causes: • Defective main control board of the peripheral • Defective BICU or IOB • Disconnected peripheral