Code: 162

Description: IPU PCIE Communication error
The link up interrupt did not proceed from the LYRA when the main switch was turned on or when recovering from the energy saver mode.
Causes: Defective IPU
Defective BCU

Code: 165

Description: Copy Data Security Unit error
The copy data security board is not detected when the copy data security function is set "ON" with the initial setting.
A device check error occurs when the copy data security function is set to "ON" with the initial setting.
Causes: • Incorrect installation of the copy data security board • Defective copy data security board

Code: 202

Description: Polygon motor error 1: ON timeout
The polygon mirror motor does not reach the targeted operating speed within 10 sec. after turning on or changing speed
Causes:

Code: 203

Description: Polygon motor error 2: OFF timeout
The polygon mirror motor does not leave the READY status within 3 sec. after the polygon motor switched off.
Causes:

Code: 204

Description: Polygon motor error 3: XSCRDY signal error
The SCRDY_N signal remains HIGH for 200 ms while the LD unit is firing.
Causes: • Polygon motor/driver board harness loose or broken • Polygon motor/driver board defective • Laser optics unit defective • IPU defective

Code: 220

Description: Laser synchronizing detection error: start position LD0
The laser synchronizing detection signal for the start position of the LDB is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally
Causes: • The Copy Data Security Unit card not installed • The Copy Data Security Unit card is installed, but it is not the correct type for the machine.

Code: 221

Description: Laser synchronizing detection error: start position LD1
The laser synchronizing detection signal for the start position of the LDB is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally.
Causes: • The Copy Data Security Unit card not installed • The Copy Data Security Unit card is installed, but it is not the correct type for the machine.

Code: 230

Description: FGATE ON error
The FGATE signal does not assert within the prescribed time. (The BICU generates the FGATE signal and sends it to the LD unit when the registration sensor switches on.)
Causes: