Description: Application Item Error The number of executed application items on the operation panel reach the maximum limit for the operation panel structure.
Description: Controller Board Mismatch The information on the controller board does not match that of the machine
Causes: -01 - • Defective BCU • NVRAM Replacement error 1. Install the previous NVRAM. 2. Input the serial number with SP5811-003, and turn the main power switch off/on. -02 - • Defective NVRAM • Defective controller 1. Update the controller firmware. 2. Install a new NVRAM, and turn off and on the main power switch after SC995-002 has occurred. -03 - • Incorrect type controller installed • Defective controller 1. Replace the controller with the correct type. -04 - • Incorrect model controller installed. 1. Replace the controller with the correct model.
Description: Software Error 3: Cannot select application function An application does not start after the user pushed the correct key on the operation panel.
Causes: • Software bug • A RAM or DIMM option necessary for the application is not installed or not installed correctly.
Description: Software Error 4: Application cannot start Register processing does not operate for an application within 60 s after the machine power is turned on. No applications start correctly, and all end abnormally.
Causes: • Software bug • A RAM or DIMM option necessary for the application is not installed or not installed correctly.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.