Các lỗi thường gặp

Code :
  • Code: 352
  • Description: ID sensor error 3
    For 2 s during the ID sensor pattern check, the ID sensor pattern edge voltage is not 2.5V or the pattern edge is not detected within 800 ms.
  • Causes: • ID sensor defective
    • ID sensor harness disconnected
    • ID sensor connector defective
    • IOB defective
    • ID sensor pattern not written correctly
    • Incorrect image density
    • Charge power pack defective
    • ID sensor dirty
  • Code: 353
  • Description: ID sensor error 4
    One of the following ID sensor output voltages is detected at ID sensor initialization. . Vsg < 4.0V when the maximum PWM input (255) is applied to the ID sensor. . Vsg . 4.0V when the minimum PWM input (0) is applied to the ID sensor.
  • Causes: • ID sensor defective
    • ID sensor harness disconnected
    • ID sensor connector defective
    • IOB defective
    • ID sensor pattern not written correctly
    • Incorrect image density
    • Charge power pack defective
    • ID sensor dirty
  • Code: 354
  • Description: ID sensor error 5
    Vsg falls out of the adjustment target (4.0 ± 0.2V) during Vsg checking
  • Causes: • ID sensor defective
    • ID sensor harness disconnected
    • ID sensor connector defective
    • IOB defective
    • ID sensor pattern not written correctly
    • Incorrect image density
    • Charge power pack defective
    • ID sensor dirty
  • Code: 355
  • Description: ID sensor error 6
    The Vp value, which measures the reflectivity of the ID sensor pattern, was not in the range of –70V to –400V.
  • Causes: • Potential sensor defective
    • Potential sensor harness defective
    • Potential sensor disconnected
    • IOB defective
    • OPC unit connector defective
    • Charge corona power pack defective
    • Charge corona wire dirty, broken
  • Code: 401
  • Description: Transfer output abnormal
    When the transfer is output, the feedback voltage remains higher than 4V for 60 ms.
  • Causes: • Transfer power pack defective
    • Transfer current terminal, transfer power pack disconnected, damaged connector
  • Code: 402
  • Description: Transfer output abnormal release detection
    When the transfer is output, there is hardly any feedback voltage within 60 ms even with application of 24% PWM.
  • Causes: • Transfer power pack defective
    • Transfer unit harness disconnected
    • Transfer connector loose, defective
  • Code: 430
  • Description: Quenching lamp error
    At the completion of auto process control initialization, the potential of the drum surface detected by the potential sensor is more than –400V, the prescribed value.
  • Causes: • Quenching lamp defective
    • Quenching lamp harness disconnected
    • Quenching lamp connector loose,
    defective
  • Code: 440
  • Description: Main motor lock
    The main motor lock signal remains low for 2 seconds while the main motor is on.
  • Causes: • Drive mechanism overloaded
    • Motor driver board defective