Description: FGATE OFF error: YT he PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [Y]. The PFGATE ON signal still asserts when the next job starts.
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board.
Code: 234
Description: FGATE ON error: M The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [M].
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board.
Code: 235
Description: FGATE OFF error: M The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [M]. The PFGATE ON signal still asserts when the next job starts.
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board.
Code: 236
Description: FGATE ON error: C The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [C].
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board.
Code: 237
Description: FGATE OFF error: C The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [C]. The PFGATE ON signal still asserts when the next job starts.
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board.
Code: 240
Description: LD error: Bk The BICU detects LDB error a few times consecutively when LDB unit turns on after LDB initialization.
Causes: Worn-out LD. Disconnected or broken harness of the LD
Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the BICU.
Code: 241
Description: LD error: Y The BICU detects LDB error a few times consecutively when LDB unit turns on after LDB initialization.
Causes: Worn-out LD. Disconnected or broken harness of the LD
Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the BICU.
Code: 242
Description: LD error: M The BICU detects LDB error a few times consecutively when LDB unit turns on after LDB initialization.
Causes: Worn-out LD. Disconnected or broken harness of the LD
Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the BICU.