Các lỗi thường gặp

Code :
  • Code: 374
  • Description: TD sensor adjustment error: C
    During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.7V) +- 0.2V
  • Causes: Heat seal not removed from a new developer pack. TD harness sensor disconnected, loose or defective. TD sensor defective. Harness between TD sensor and drawer disconnected, defective.
  • Remedy: 1. Remove the heat seal from each PCDU. 2. Replace the defective PCDU.
  • Code: 375
  • Description: TD sensor adjustment error: Y
    During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.7V) +- 0.2V
  • Causes: Heat seal not removed from a new developer pack. TD harness sensor disconnected, loose or defective. TD sensor defective. Harness between TD sensor and drawer disconnected, defective.
  • Remedy: 1. Remove the heat seal from each PCDU. 2. Replace the defective PCDU.
  • Code: 380
  • Description: Drum gear position sensor error: K
    The machine does not detect the drum position signal for 3 seconds at the drum phase adjustment.
  • Causes: • Dirty or defective drum gear position sensor
  • Remedy: 1. Clean the drum gear position sensor. 2. Check the harness connection. 3. Replace the drum gear position sensor. 4. Replace the PCDU.
  • Code: 381
  • Description: Drum gear position sensor error: M
    The machine does not detect the drum position signal for 3 seconds at the drum phase adjustment.
  • Causes: • Dirty or defective drum gear position sensor
  • Remedy: 1. Clean the drum gear position sensor. 2. Check the harness connection. 3. Replace the drum gear position sensor. 4. Replace the PCDU.
  • Code: 382
  • Description: Drum gear position sensor error: C
    The machine does not detect the drum position signal for 3 seconds at the drum phase adjustment.
  • Causes: • Dirty or defective drum gear position sensor
  • Remedy: 1. Clean the drum gear position sensor. 2. Check the harness connection. 3. Replace the drum gear position sensor. 4. Replace the PCDU.
  • Code: 383
  • Description: Drum gear position sensor error: Y
    The machine does not detect the drum position signal for 3 seconds at the drum phase adjustment.
  • Causes: • Dirty or defective drum gear position sensor
  • Remedy: 1. Clean the drum gear position sensor. 2. Check the harness connection. 3. Replace the drum gear position sensor. 4. Replace the PCDU.
  • Code: 396
  • Description: Drum/Development motor error: K
    The machine detects a High signal from the drum/development motor for 2 seconds after the drum/development motor turned on.
  • Causes: • Overload on the drum/development motor • Defective drum/development motor • Defective harness • Shorted 24 V fuse on the PSU • Defective interlock system
  • Remedy: 1. Check or replace the harness. 2. Replace the drum/development motor. 3. Replace the 24V fuse on the PSU.
  • Code: 397
  • Description: Drum/Development motor error: M
    The machine detects a High signal from the drum/development motor for 2 seconds after the drum/development motor turned on.
  • Causes: • Overload on the drum/development motor • Defective drum/development motor • Defective harness • Shorted 24 V fuse on the PSU • Defective interlock system
  • Remedy: 1. Check or replace the harness. 2. Replace the drum/development motor. 3. Replace the 24V fuse on the PSU.