Description: Remote Service Modem: Communication error CTL A modem communication error occurred at dialing or when the machine was turned on. This error is displayed only if @ Remote is operating.
Causes: The @Remote SP settings are not correct, or the telephone line, modem board, or wireless LAN card is not connected.
Remedy: • Incorrect SP settings • Disconnected telephone line • Disconnected modem board • Wireless LAN card not connected
Description: @Remote service ID2 mismatch error 1 CTL The ID2 in the individual certificate does not match the ID2 in the NVRAM on the controller board.
Causes: • The controller board in this machine has already been used in a machine in which RC Gate was installed. • The controller board NVRAM in this machine has already been used in a machine in which RC Gate was installed.
Remedy: If an error occurs at installation of the RC Gate: • Check that the individual certificate is correct for the NVRAM in the machine and that the ID2 is correct. • Reinstall the RC Gate after writing the common certificate. If an error occurs after installation of the RC Gate: • Clear the RC Gate data. • Check that the individual certificate is correct for the NVRAM in the machine and that the ID2 is correct. • Reinstall the RC Gate after writing the common certificate.
Description: Engine start up error CTL The ready signal from the engine board was not detected.
Causes: Case 1 • No /ENGRDY signal asserted at power on, or when machine left low power mode. • No response from EC from engine within the specified time at power on. • No response from PC from engine within the specified time at power on. • No response from SC from engine within the specified time at power on (MFP module only). • Write to Rapi driver failed (no destination found at PCI). Case 2 • Unexpected error occurred after /ENGRDY signal asserted.
Remedy: • Check the connections between the controller and BCU • Replace the BCU for 100% failure • If occurrence of the error is sporadic, the firmware may need to be updated, or the controller board or PSU requires replacement
Description: Memory chip at TD sensor: Communication error Retry of memory chip communication fails three times after the machine has detected the memory chip communication error.
Causes: • Damaged memory chip data • Disconnected inter face • No memory chip on the development unit • Noise
Remedy: • Replace the PCDU. • Replace the BCU.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.