Description: Drum motor error: M
The motor is trying to rotate at power on or during normal operation but there is an excessive load on the drum shaft. The motor has no traction (due to a bent cleaning blade, for example).
Causes: • Drum motor harness loose, broken, defective • Drum motor defective • DTMB defective
Code: SC398
Description: Drum motor error: C
The motor is trying to rotate at power on or during normal operation but there is an excessive load on the drum shaft. The motor has no traction (due to a bent cleaning blade, for example).
Causes: • Drum motor harness loose, broken, defective • Drum motor defective • DTMB defective
Code: SC399
Description: Drum motor error: Y
The motor is trying to rotate at power on or during normal operation but there is an excessive load on the drum shaft. The motor has no traction (due to a bent cleaning blade, for example).
Causes: • Drum motor harness loose, broken, defective • Drum motor defective • DTMB defective
Code: SC400
Description: ID sensor error: Calibration
Before adjustment Vsg_reg<0.5 but Vsg_reg could not be adjusted to the target Vsg_reg = 4.0+-0.2V during process control.
Causes: • ID sensor harness disconnected, loose, defective • ID sensor dirty • ID sensor defective • ITB unit drawer connector dirty
Code: SC410
Description: ID sensor error: Development K
Development gamma for black, magenta, cyan, or yellow is not within range (0.3 to 6.0). Process control halts when this SC is issued.
Causes: • Toner density abnormal. Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61). • LD sensor harness loose, broken, defective • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective)
Code: SC411
Description: ID sensor error: Development M
Development gamma for black, magenta, cyan, or yellow is not within range (0.3 to 6.0). Process control halts when this SC is issued.
Causes: • Toner density abnormal. Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61). • LD sensor harness loose, broken, defective • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective)
Code: SC412
Description: ID sensor error: Development C
Development gamma for black, magenta, cyan, or yellow is not within range (0.3 to 6.0). Process control halts when this SC is issued.
Causes: • Toner density abnormal. Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61). • LD sensor harness loose, broken, defective • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective)
Code: SC413
Description: ID sensor error: Development Y
Development gamma for black, magenta, cyan, or yellow is not within range (0.3 to 6.0). Process control halts when this SC is issued.
Causes: • Toner density abnormal. Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61). • LD sensor harness loose, broken, defective • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective)