Description: Duplex unit fan error
The lock signal remained HIGH for 5 sec. while the fan that draws air out of the duplex unit was operating.
Causes: • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
Code: SC535
Description: Development Intake Fan Error
The lock signal remained HIGH for 5 sec. while the fan in the Y development unit was operating
Causes: • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
Code: SC536
Description: Development Intake Fan Error: Y
The lock signal remained HIGH for 5 sec. while the fan in the development unit was operating.
Causes: • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
Code: SC537
Description: Development Intake Fan Error: C
The lock signal remained HIGH for 5 sec. while the fan in the development unit was operating.
Causes: • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
Code: SC538
Description: Development Intake Fan Error: M
The lock signal remained HIGH for 5 sec. while the fan in the development unit was operating.
Causes: • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
Code: SC539
Description: Development Intake Fan Error: K
The lock signal remained HIGH for 5 sec. while the fan in the development unit was operating.
Causes: • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
Code: SC540
Description: Fusing/exit motor error
Motor operation was detected abnormal at power on.
Causes: • Check inside the fusing unit for any obstructions • Motor harness loose, broken, defective • Motor or its driver board defective
Code: SC541
Description: Heating roller thermistor (center) error 1
The "floating" (non-contact) thermistor at the center of the heating roller is not operating correction.