Các lỗi thường gặp

Code :
  • Code: SC562
  • Description: Heating roller non-contact thermistor error 2
    After the main switch is turned on or the cover is closed, the heating roller temperature does not reach the ready temperature within 100 sec. after the heater switches on. -or- The heating roller did not reach the ready temperature within 150 sec.
  • Causes: • Do SP5810 to cancel the SC fusing code • Defective hot roller thermistor • Heating roller disconnected, defective
  • Code: SC563
  • Description: Heating roller non-contact thermistor error 3
    The thermistor 2 (of the heating roller) detected a temperature over 250°C 10 times within 1 sec.
  • Causes: • Do SP5810 to cancel the SC fusing code. • TRIAC short, AC drive board defective • VBCU defective
  • Code: SC564
  • Description: Heating roller non-contact thermistor error 3
    The thermistor detected a temperature over 260°C.
  • Causes: • Do SP5810 to cancel the SC fusing code. • TRIAC short, AC drive board defective • VBCU defective
  • Code: SC565
  • Description: Heating roller fusing lamp on error
    After fusing belt reached warm-up temperature, the heating roller fusing lamp remained on for 20 sec. while the hot roller was not rotating.
  • Causes: • Do SP5810 to cancel the SC fusing code. • Thermistor damaged, or out of position • Fusing lamp disconnected, broken
  • Code: SC566
  • Description: Heating roller non-contact thermistor 3
    Thermistor detected a temperature less than 0 degrees more than three times.
  • Causes: • Do SP5810 to cancel the error. • Hot roller thermistor connector disconnected, loose, broken, or defective.
  • Code: SC569
  • Description: Pressure roller lift error 2
    Pressure roller lift motor not operating correctly. (No signal to indicate completion of operation.)
  • Causes: • Pressure roller lift sensor connection loose, broken, damaged • Clean the pressure roller lift sensor • Pressure roller lift harness loose, broken, damage • Pressure roller lift motor blocked by an obstruction • Pressure roller lift motor defective
  • Code: SC570
  • Description: Development intake fan error
    Fan motor not operating correctly.
  • Causes: • Fan harness loose, broken, defective • Fan overload due to physical obstruction • Fan motor defective
  • Code: SC571
  • Description: Ozone exhaust fan (FC) error
    The fan of the middle ozone filter box not operating correctly.
  • Causes: • Fan harness loose, broken, defective • Fan overload due to physical obstruction • Fan motor defective