Description: Heating roller thermistor (center) error 2
The thermistor at the center of the heating roller detected an abnormally high temperature (over 250°C)
Causes: • Do SP5810 to cancel the SC fusing code. • TRIAC short, AC drive board defective • VBCU defective
Code: SC544
Description: Heating roller thermistor (center) error 3
The thermistor detected a temperature over 260°C..
Causes: • Do SP5810 to cancel the SC fusing code. • TRIAC short, AC drive board defective • VBCU defective
Code: SC545
Description: Lamp remains on
After hot roller reaches warm-up temperature, the center fusing lamps in the heating roller remained on at full capacity after reaching the warm-up temperature while the hot roller was not rotating.
Causes: • Do SP5810 to cancel the SC fusing code. • Heating roller thermistor damaged, or out of position • Fusing lamp disconnected, broken
Code: SC546
Description: Heating roller thermistor error (side)
The temperature measured by the heating roller thermistor does not reach 0°C after 50 sec. and remains over this temperature for 10 readings.
Causes: • Loose connection of the heating roller thermistor • Defective heating roller thermistor
Code: SC547
Description: Zero cross error
When the main switch is turned on, the machine checks how many zero-cross signals are generated within 500 ms. This SC code is issued if the number of zero-cross signals detected is not within specification. Note: Zero cross signals, generated from an ac power supply, are used to generate a trigger pulses to control the applied power accurately.
Causes: • Do SP5810 to cancel the SC fusing code. • Electrical noise on the power supply line • Fusing relay damaged, replace the AC drive board.
Code: SC549
Description: Heating roller thermistor (center): software error
The thermistor detected a temperature over 250°C 10 times within 1 sec.
Causes: • Do SP5810 to cancel the SC fusing code. • TRIAC short, AC drive board defective • VBCU defective
Code: SC550
Description: Heating roller thermistor 3 (side): hardware error
The thermistor detected a temperature over 260°C.
Causes: • Do SP5810 to cancel the SC fusing code. • TRIAC short, AC drive board defective • VBCU defective
Code: SC551
Description: Pressure roller thermistor error 1
The temperature measured by the pressure roller thermistor did not reach 0°C after 10 attempts.
Causes: • Do SP5810 to cancel the SC fusing code. • Loose connection of the pressure roller thermistor • Thermistor positioned incorrectly • Defective pressure roller thermistor