Các lỗi thường gặp

Code :
  • Code: SC735
  • Description: Staple Junction Gate Motor Error: B830
    The staple tray junction gate HP sensor did not detect the gate at the home position within 200 ms after two attempts. -or- The HP sensor twice detected the gate at the home position for more than 200 ms after it was supposed to open.
  • Causes: • Junction gate did not arrive at the home position within the specified time • Junction gate did not leave the home position within the specified time
  • Code: SC736
  • Description: Pre-Stack Junction Gate Motor Error: 3K Finisher B830
    The pre-stack junction gate HP sensor did not detect the gate at the home position for within 200 ms after two attempts. -or- The HP sensor twice detected the gate at the home position for more than 200 ms after it was supposed to open.
  • Causes: • Junction gate did not arrive at the home position within the specified time • Junction gate did not leave the home position within the specified time
  • Code: SC737
  • Description: Pre-Stack Transport Motor Error: B830
    The pre-stack transport motor is not operating.
  • Causes: • Motor harness loose, broken, defective • Motor is blocked by an obstruction • Motor defective • Finisher main control board defective
  • Code: SC738
  • Description: Pre-Stack Junction Gate Release Motor Error: B830
    The pre-stack junction gate release HP sensor did not detect the gate at the home position within 200 ms after two attempts. -or- The HP sensor twice detected the gate at the home position for more than 200 ms after it was supposed to open.
  • Causes: • Junction gate did not arrive at the home position within the specified time • Junction gate did not leave the home position within the specified time
  • Code: SC740
  • Description: Finisher corner stapler motor error (B830)
    The stapler motor does not switch off within the prescribed time after operating. The 1st detection failure causes a jam error, and the 2nd failure causes this SC code.
  • Causes: • Staple jam • Number of sheets in the stack exceeds the limit for stapling • Stapler motor disconnected, defective
  • Code: SC741
  • Description: Finisher corner stapler rotation motor error
    The stapler does not return to its home position within the specified time after stapling. The 1st detection failure causes a jam error, and the 2nd failure causes this SC code.
  • Causes: • Stapler rotation motor disconnected, defective • Stapler rotation motor overloaded due to obstruction • Stapler rotation HP sensor disconnected, defective
  • Code: SC742
  • Description: Finisher stapler movement motor error
    The stapler HP sensor is not activated within the specified time after the stapler motor turned on. The 1st detection failure causes a jam error, and the 2nd failure causes this SC code.
  • Causes: • Stapler movement motor disconnected, defective • Stapler movement motor overloaded due to obstruction • Stapler HP sensor disconnected, defective
  • Code: SC743
  • Description: Booklet stapler motor error 1
    The front stapler unit saddle-stitch motor does not start operation within the specified time. The 1st detection failure causes a jam error, and the 2nd failure causes this SC code.
  • Causes: • Front motor disconnected, defective • Front motor overloaded due to obstruction