Description: TD sensor adjustment error (K). During TD sensor initialization, the TD sensor output voltage (Vt) cannot be adjusted to the target range (target value ± 0.2V). Details: TD sensor initialization adjusts the TD sensor control voltage (Vtcnt) in order to adjust the TD sensor output voltage (Vt) to target value ± 0.2V. Adjustment flow: 1. Developer presence detection 2. Developer not detected. OK: Proceeds to Vtcnt adjustment. NG: SC336-0X 3. TD sensor calibration (Fluctuate Vtcnt and measure Vt) 4. TD sensor calibration result judgment OK: TD sensor calibration succeeded. NG: SC360-0X
Causes: • TD sensor defective • Loose connection • Harness broken • Developer is not new
Remedy: • Replace the TD sensor. • Replace the development unit.
Code: SC360-02
Description: TD sensor adjustment error (C). During TD sensor initialization, the TD sensor output voltage (Vt) cannot be adjusted to the target range (target value ± 0.2V). Details: TD sensor initialization adjusts the TD sensor control voltage (Vtcnt) in order to adjust the TD sensor output voltage (Vt) to target value ± 0.2V. Adjustment flow: 1. Developer presence detection 2. Developer not detected. OK: Proceeds to Vtcnt adjustment. NG: SC336-0X 3. TD sensor calibration (Fluctuate Vtcnt and measure Vt) 4. TD sensor calibration result judgment OK: TD sensor calibration succeeded. NG: SC360-0X
Causes: • TD sensor defective • Loose connection • Harness broken • Developer is not new
Remedy: • Replace the TD sensor. • Replace the development unit.
Code: SC360-03
Description: TD sensor adjustment error (M). During TD sensor initialization, the TD sensor output voltage (Vt) cannot be adjusted to the target range (target value ± 0.2V). Details: TD sensor initialization adjusts the TD sensor control voltage (Vtcnt) in order to adjust the TD sensor output voltage (Vt) to target value ± 0.2V. Adjustment flow: 1. Developer presence detection 2. Developer not detected. OK: Proceeds to Vtcnt adjustment. NG: SC336-0X 3. TD sensor calibration (Fluctuate Vtcnt and measure Vt) 4. TD sensor calibration result judgment OK: TD sensor calibration succeeded. NG: SC360-0X
Causes: • TD sensor defective • Loose connection • Harness broken • Developer is not new
Remedy: • Replace the TD sensor. • Replace the development unit.
Code: SC360-04
Description: TD sensor adjustment error (Y). During TD sensor initialization, the TD sensor output voltage (Vt) cannot be adjusted to the target range (target value ± 0.2V). Details: TD sensor initialization adjusts the TD sensor control voltage (Vtcnt) in order to adjust the TD sensor output voltage (Vt) to target value ± 0.2V. Adjustment flow: 1. Developer presence detection 2. Developer not detected. OK: Proceeds to Vtcnt adjustment. NG: SC336-0X 3. TD sensor calibration (Fluctuate Vtcnt and measure Vt) 4. TD sensor calibration result judgment OK: TD sensor calibration succeeded. NG: SC360-0X
Causes: • TD sensor defective • Loose connection • Harness broken • Developer is not new
Remedy: • Replace the TD sensor. • Replace the development unit.
Code: SC361-01
Description: TD sensor output error: Upper Limit (K). The TD sensor output (Vt) (SP3-210-001 to 004) exceeded 4.7 V 20 times consecutively.
Causes: • Toner density extremely low
Remedy: • Check the toner supply system.
Code: SC361-02
Description: TD sensor output error: Upper Limit (C). The TD sensor output (Vt) (SP3-210-001 to 004) exceeded 4.7 V 20 times consecutively.
Causes: • Toner density extremely low
Remedy: • Check the toner supply system.
Code: SC361-03
Description: TD sensor output error: Upper Limit (M). The TD sensor output (Vt) (SP3-210-001 to 004) exceeded 4.7 V 20 times consecutively.
Causes: • Toner density extremely low
Remedy: • Check the toner supply system.
Code: SC361-04
Description: TD sensor output error: Upper Limit (Y). The TD sensor output (Vt) (SP3-210-001 to 004) exceeded 4.7 V 20 times consecutively.