Mã lỗi Ricoh Aficio MPC7501 — Trang 21/44

Code: SC485

Description: Used toner bottle motor error
The lock signal of the used toner bottle motor remains HIGH for more than 600 ms.
Causes: • Used toner bottle harness loose, broken, defective • Used toner bottle motor defective

Code: SC487

Description: Used toner bottle set error
The set sensor of the used toner bottle remains LOW for more than 500 ms. (The sensor goes HIGH when the bottle is installed correctly.)
Causes: • Used toner bottle not installed • Remove used toner bottle and reinstall correctly

Code: SC488

Description: Used toner transport lock
Used toner cannot be transported to the used toner bottle.
Causes: • Blockage in the line to the used toner bottle

Code: SC490

Description: MUSIC sensor error
One or more of the MUSIC sensors is not functioning normally.
Causes: • MUSIC sensor harness loose, broken, defective • Sensor defective

Code: SC495

Description: ITB encoder sensor error
The ITB encoder sensor that reads the encoded strip on the ITB is not functioning properly.
Causes: • Sensor dirty • Sensor harness loose, broken, defective • Sensor out of position because installed incorrectly • ITB installed incorrectly

Code: SC496

Description: MUSIC sensor error
The MUSIC sensor detected an abnormal pattern on the ITB because: • ADC exceeded upper or lower limit. • The pattern used to calculate the amount of skew is abnormal. • The reading of the pattern exceeded the length of time the LED projected light. • LED light could not be adjusted correctly.
Causes: • ITB installed incorrectly • Inspect ITB belt for damage, replace • MUSIC pattern abnormal; do a forced process control (SP3821) and check the result. • MUSIC sensor defective or disconnected

Code: SC497

Description: Temperature and humidity sensor error: M PCU
The thermistor output of the temperature and humidity sensor above the M PCU was not within the prescribed range (0.5V to 4.2V)
Causes: • Temperature and humidity sensor harness disconnected, loose, defective • Temperature and humidity sensor defective

Code: SC498

Description: Temperature and humidity sensor error: Toner Bottle
The thermistor output of the temperature and humidity sensor below the used toner bottle was not within the prescribed range (0.5V to 4.2V)
Causes: • Temperature and humidity sensor harness disconnected, loose, defective • Temperature and humidity sensor defective