Các lỗi thường gặp

Code :
  • Code: SC161
  • Description: IPU error
    Communication error between IPU, SBU, and VBCU.
  • Causes: • Check harness connections between SBU and IPU/VBCU • IPU defective • VBCU defective
  • Code: SC161-1
  • Description: An error occurred when the ASIC executed a self-diagnostic report on the BICU.
  • Causes: • Defective BICU • Defective connection between BICU and SBU
  • Code: SC161-2
  • Description: The machine detects an error during an access to the Ri.
  • Causes: • Defective BICU board
  • Code: SC161-3
  • Description: The IPU fails to configure or initialize the DRAM.
  • Causes: • Defective BICU board
  • Code: SC165
  • Description: Illegal Copy Prevention Error
    An abnormality was detected with the ICIB board at power on.
  • Causes: • ICIB connected incorrectly • ICIB defective
  • Code: SC180
  • Description: Scanner fan lock The fan motor next to the SIOB did not switch on within 10 sec. after the CPU issued the ON signal.
  • Causes: • Fan defective • Foreign object interfering with operation of fan • Motor harness loose, disconnected, or broken • SIOB defective
  • Code: SC181
  • Description: Scanner Fan Error: Lamp Stabilizer
    The exposure lamp regulator fan is not rotating.
  • Causes: • Check the fan connections • Fan defective • Check SBU connection • Check SIOB connection • SBU defective • SIOB defective
  • Code: SC182
  • Description: Scanner Fan Error: Right Side
    The fan located on the right side of the exposure unit is not rotating.
  • Causes: • Check the fan connections • Fan defective • Check SBU connection • Check SIOB connection • SBU defective • SIOB defective