Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio MPC7501 — Trang 29/44

Code: SC624

Description: Mailbox-to-copier communication error
Communication between the mailbox and copier is interrupted. An ACK/NCK signal was not received within 100 ms after a data frame is sent and 3 retries failed.
Causes: • Mailbox cable disconnected, defective • Mailbox main board defective • VBCU defective • PSU defective

Code: SC625

Description: VBCU-DTMB (DMC1) communication error
Communication between the VBCU and DMC (main) was interrupted. An ACK/NAK signal was not received within 100 ms after a data frame was sent and three retries failed.
Causes: • Check the DTMB harness connections at the DTMB and VBCU • DTMB defective • PSU defective • VBCU defective • 5V power supply defective

Code: SC626

Description: VBCU-DTMB (DMC2) communication error
Communication between the VBCU and DMC (sub) was interrupted. An ACK/NAK signal was not received within 100 ms after a data frame was sent and three retries failed.
Causes: • Check the DTMB harness connections at the DTMB and VBCU • DTMB defective • VBCU defective • PSU defective

Code: SC627

Description: VBCU-DTMB (TMC) communication error
Communication between the VBCU and TMC was interrupted. An ACK/NAK signal was not received within 100 ms after a data frame was sent and three retries failed.
Causes: • DTMB harness loose, broken, defective • DTMB defective • VBCU defective • PSU defective

Code: SC636

Description: SD card error
Causes: • There is no expanded authentication module in the machine. • The SD card is damaged or the authentication module is corrupted. • There is no DESS module in the machine.

Code: SC641

Description: Engine-Controller Communication Error: No Response
There was no response to a frame sent from the controller board to the engine.
Causes: • Cycle the machine off/on.

Code: SC670

Description: Engine start failure
The engine did not respond within 30s after power on, or the engine went down suddenly at power on or during warm up because a communication reset occurred between the VBCU and the controller.
Causes: • VBCU installed incorrectly • VBCU defective

Code: SC671

Description: Incorrect board detected
An illegal engine board was detected at power on.
Causes: • Replace BICU
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie