Description: Pre-punch side fence HP error
Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 pulses) (1st detection, jam, 2nd detection, SC error) -or- Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 600 pulses) (1st detection, jam, 2nd detection, SC error)
Causes: • Side jogger motor (M302) connector loose, broken, defective • Motor overload • Motor defective • Pre-punch jogger HP sensor (S301) connector loose, broken, defective • Sensor (S301) defective
Code: SC792-20
Description: Output belt 1 HP error
Detected at HP after the time prescribed to leave the HP had elapsed (more than 200 pulses) (1st detection, jam, 2nd detection, SC error) -or- Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 2125 pulses) (1st detection, jam, 2nd detection, SC error)
Causes: • Output belt 1 motor (M401) connector loose, broken, defective • Motor overload • Motor defective • Output belt 1 HP sensor (S401) connector loose, broken, defective • Sensor defective
Code: SC792-21
Description: Output belt 2 HP error
Detected at HP after the time prescribed to leave the HP had elapsed (more than 200 pulses) (1st detection, jam, 2nd detection, SC error) -or- Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 3130 pulses) (1st detection, jam, 2nd detection, SC error)
Causes: • Output belt 2 motor (M402) connector loose, broken, defective • Motor overload • Motor defective • Output belt 2 HP sensor (S402) connector loose, broken, defective • Sensor defective
Code: SC792-22
Description: Stack height error
Stack height sensor remained ON while moving toward the top. -or- The sensor did not go ON within 6 sec. after the motor turned on.
Description: Stacker error
Although the stacker was full at the start and end of stacker operation with the stacker full (stacker sensors ON together), no documents were detected (also when documents were leaning) -or- Although the stacker was detected full with the stacker stopped, no documents were detected within 2 sec. (1st detection jam, 2nd detection SC error)
Causes: • Stacker HP sensor (S501) connector loose, broken, defective, or sensor defective • Stacker height HP sensor (S502) connector loose, broken, defective, or sensor defective • Stacker detect sensor (S504) loose, broken, defective, or sensor defective
Code: SC792-3
Description: Pre-punch jogger roller HP error
Detected at HP after the time prescribed to leave the HP had elapsed (more than 36 pulses) (1st detection, jam, 2nd detection, SC error) -or- Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 22 pulses) (1st detection, jam, 2nd detection, SC error)
Causes: • Jog roller lift motor (M305) connector loose, broken, defective • Motor overload • Motor defective • Jog roller lift HP sensor (S309) connector loose, broken, defective • Sensor defective
Code: SC792-4
Description: Punch defective
One or more of the following occurred: • Punch unit not detected at initialization. • No motor rotation detected at HP at 30 ms after the DC motor turned on • No encoder pulse detected at HP at 5 ms after the DC motor turned on • Not detected at HP at 400 ms after the DC motor turned on
Causes: • Punch motor (M304) connector loose, broken, defective • Motor overload • Motor defective • Punch HP sensor (S302) connector loose, broken, defective, or sensor defective • Punch encoder sensor (S303) connector loose, broken, defective, or sensor defective