Các lỗi thường gặp

Code :
  • Code: SC792-5
  • Description: Paddle roller HP error
    Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)
  • Causes: • Paddle roller lift motor (M603) connector loose, broken, defective • Motor overload • Motor defective • Paddle roller HP sensor (S602) connector loose, broken, defective • Sensor defective
  • Code: SC792-6
  • Description: Jogger fence 1 error
    Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)
  • Causes: • Jog fence 1 motor (M604) connector, loose, broken, defective • Motor defective • Motor overload • Side fence 1 HP sensor (S601) connector, loose, broken, defective • Sensor defective
  • Code: SC792-7
  • Description: Jogger fence 2 error
    Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)
  • Causes: • Jog fence 2 motor (M606) connector, loose, broken, defective • Motor defective • Motor overload • Side fence HP sensor 1 (S611) connector loose, broken, defective • Sensor defective
  • Code: SC792-8
  • Description: Stack tamper HP error
    Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)
  • Causes: • Stack tamper motor (M607) connector, loose, broken, defective • Motor defective • Motor overload • Stack tamper HP sensor (S612) connector loose, broken, defective • Sensor defective
  • Code: SC792-9
  • Description: Pre-bind jogger clamp HP error
    Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)
  • Causes: • Spine clamp motor (M605) connector loose, broken, defective • Motor defective • Motor overload • Clamp HP sensor (S603) connector loose, broken, defective • Sensor defective
  • Code: SC816
  • Description: Energy save I/O subsystem error
    An error was detected in the signal from the ASIC (controller board) which controls the STR (Suspend to RAM) function. Note: STR is a feature of this machine that minimizes energy consumption while the machine is in the energy saver mode.
  • Causes: • Reboot the machine. • Replace the controller board.
  • Code: SC817
  • Description: Boot loader error
    The boot loader cannot read one of the following: self-diagnostic module, kernel, or one of the files of the root file system, or the check of one of these items on the system SD card failed.
  • Causes: • File or module on the system SD card is corrupted • File or module on the system SD card is illegal • Make sure that the system SD card is the one designed for the machine • Replace controller board.
  • Code: SC819
  • Description: Fatal kernel error
    Due to a control error, a RAM overflow occurred during system processing. One of the following messages was displayed on the operation panel.
  • Causes: • System program defective • Controller board defective • Optional board defective • Replace controller firmware