Các lỗi thường gặp

Code :
  • Code: 460
  • Description: DC Separation Corona Output Error A dc separation feedback voltage of less than 0.5 V was detected after more than 200 ms.
  • Causes: • High voltage cable disconnected, damaged • T/S power pack defective
  • Remedy:
  • Code: 508
  • Description: Cutter Error The left and right cutter HP sensors remained on or off more than 2 sec.
  • Causes: • HP sensors on the left and right side loose, disconnected, defective • Cutter motor harness damaged, defective • Cutter motor defective Note: Paper can be fed from the bypass table if the roll feeder or paper cassette is not operating.
  • Remedy:
  • Code: 520
  • Description: Main Motor Error After the motor started, the main motor lock signal remained HIGH for 5 sec.
  • Causes: • Physical obstruction blocking motor • Motor harness damaged, defective • Motor defective
  • Remedy:
  • Code: 521
  • Description: Drum Motor Error After the motor started, the drum motor lock signal remained HIGH for 5 sec.
  • Causes: • Physical obstruction blocking motor • Motor harness damaged, defective • Motor defective
  • Remedy:
  • Code: 522
  • Description: Fusing Unit Drive Motor Error After the motor started, the fusing motor lock signal remained HIGH for 5 sec.
  • Causes: • Physical obstruction blocking motor • Motor harness damaged, defective • Motor defective
  • Remedy:
  • Code: 530
  • Description: Fusing Unit Ventilation Fan Error After the motor started, the fan motor lock signal remained HIGH for 5 sec.
  • Causes: • Physical obstruction blocking motor • Motor harness damaged, defective • Motor defective
  • Remedy:
  • Code: 541
  • Description: Fusing Thermistor Errors The thermistor measured the hot roller temperature every 1 sec. for 30 sec. and the temperature remained below 5C (54F).
  • Causes: • Thermistor positioned incorrectly • Thermistor cable loose, disconnected, damaged • Thermistor defective
  • Remedy:
  • Code: 542
  • Description: Fusing Temperature Warm-up Error The hot roller did not reach the ready temperature within 4 min. 30 sec. after power on. -or- The hot roller did not reach 100°C within 130 sec. after power on.
  • Causes: • Fusing lamp connections loose, broken, defective • Fusing lamp defective • Thermistor not touching the hot roller • Thermistor defective • MCU defective
  • Remedy: The ready temperature is determined by the state of the machine at recovery: • Ready Temp. = Target Fusing Temp. (if power on or recovery starts when the hot roller is 80°C or higher). • Ready Temp. = Target Fusing Temp. – 10°C (SP1105-1 default) if power on or recovery starts when the hot roller is less that 80°C. • Ready Temp. = Target Fusing Temp. – 20°C (SP1937-3 default) if power on or recovery starts with pressure roller inching control on.