Description: Lamp error Lamp does not light at power on.
Causes: If cycling the machine power off/on does not solve the problem: • Clean the white plate • Clean the CIS glass • Lamp regulator connection loose broken, defective • CIS, IPU, BCU connection loose broken defective • Harness connection between Xenon lamp and lamp regulator loose broken defective • Harness between CIS and IPU loose, broken, defective • Harness between CIS and PSU loose, broken, defective • One or more defective: CIS, IPU, BCU, PSU, Xenon lamp
Remedy:
Code: SC144
Description: CIS communication error A serial communication error occurred with the CIS due to a PCB malfunction or loose connection.
Causes: If cycling the machine power off/on does not solve the problem: • Harness between CIS and IPU loose broken defective • Harness between CIS and PSU loose, broken, defective • CIS defective • IPU defective • BCU defective
Remedy:
Code: SC161
Description: IPU Error Three attempts to configure the Cetus chip on the IPU board failed when the machine was switched on or when machine recovered from the energy save mode.
Causes: • Replace the IPU
Remedy:
Code: SC180
Description: Left scanner fan lock The BCU detected a left scanner fan lock signal 5 sec. after the machine was switched on.
Causes: If cycling the machine power off/on does not solve the problem: • Left scanner fan harness connection to the IOB loose, broken, defective • Left scanner fan defective • IOB defective • BCU defective
Remedy:
Code: SC181
Description: Right scanner fan lock The BCU detected a right scanner fan lock signal 5 sec. after the machine was switched on.
Causes: If cycling the machine power off/on does not solve the problem: • Left scanner fan harness connection to the IOB loose, broken, defective • Left scanner fan defective • IOB defective • BCU defective
Remedy:
Code: SC186
Description: Gray balance adjustment error
Causes: The value for gray balance was detected out of range after gray adjustment.
Remedy: If cycling the machine power off/on does not solve the problem: • Clean the white strip • Clean the CIS glass • Check the following harnesses for loose, broken, or defective connectors: 1. Xe lamp to lamp regulator 2. Lamp regulator to CIS 3. CIS to IPU 4. CIS to IPU 5. IPU to IOB • One of the following boards is defective 1. CIS 2. IPU 3. IOB 4. BCU
Code: SC191
Description: Original exit roller thermistor error The original exit roller thermistor reading was abnormal.
Causes: • Thermistor connection loose, broken, defective • Thermistor short • Harness between thermistor and IOB loose, broken, defective • IOB defective • BCU defective
Remedy:
Code: SC300
Description: Charge corona output error Charge corona feedback voltage less than 0.5 V was detected for more than 200 sec after power on.
Causes: • TD power pack defective. • High voltage cable defective. • Dirty charge corona wire caused voltage leak