Các lỗi thường gặp

Code :
  • Code: 796-60
  • Description: Inserter Tray B Error PB (D391)
  • Causes: Inserter Tray B (lower tray) failed to leave its lower limit sensor within the prescribed time after the Tray B lift motor turned on. • Lift Motor: Tray B (M4) defective • Lower Limit Sensor: Tray B (S12) defective • Motor or sensor connector loose, broken, defective Inserter Tray B (lower tray) failed to arrive at its paper feed sensor within the prescribed time after the Tray B lift motor turned on. • Lift Motor: Tray B (M4) defective • Paper Feed Sensor: Tray B (S10) defective • Motor or sensor connector loose, broken, defective
  • Remedy:
  • Code: 796-61
  • Description: Relay Unit EEPROM Error PB (D391) EEPROM write error (successful completion of data write operation not detected within the prescribed time).
  • Causes: • Relay board EEPROM not installed, or installed incorrectly • EEPROM damaged • Relay board defective
  • Remedy:
  • Code: 796-62
  • Description: Relay/ Bookbinder Communication Error PB (D391) Communication error between relay unit and bookbinder.
  • Causes: • Relay I/F cable disconnected or damaged • Relay unit PCB in bookbinder damaged, not installed correctly • PCB in relay unit damaged, not installed correctly
  • Remedy:
  • Code: 796-63
  • Description: Lower Performance Mode Error PB (D391) These are the conditions that must be met before the bookbinder enters low performance mode: • The location where the error occurred has no effect on the operation of the horizontal feed path for downstream delivery. • The jam has occurred in the horizontal feed path but it can be removed easily. • The unit where the error occurred allows use of the horizontal feed path. • These conditions determine whether downstream delivery is possible after an error occurs in the bookbinder.
  • Causes: Correct the problem and release the bookbinder from the low performance mode. See Section 3 of the Perfect Binder manual for more about how to release the Perfect Binder from the low performance mode.
  • Remedy:
  • Code: 796-7
  • Description: Spine Fold HP Sensor: Right (S66) Error PB (D391) The spine fold plate did not reach the right HP sensor within the prescribed time (sensor did not go ON) after the spine fold plate motor (M29) turned on to open the fold plate, or the right HP sensor was already OFF when the spine fold plate was supposed to move from the open to the closed position. -or- The spine fold plate did not leave the right HP sensor position (sensor did not go OFF) within the prescribed time after the spine fold motor: right turned on to close the fold plate.
  • Causes: • Spine fold motor: right (M29) defective • Spine fold HP sensor: right (S66) defective • Connector loose, broken, defective
  • Remedy:
  • Code: 796-8
  • Description: Spine Fold Close Sensor: Right (S69) Error PB (D391) The right fold plate close sensor did not go ON within the prescribed time after the spine fold plate motor: right turned on to close the fold plate, or the close sensor on the right was already OFF when the spine fold plate was supposed to close the plate. -or- The right spine fold plate close sensor did not go OFF within the prescribed time after the spine fold plate motor: right turned on to open the plate, or the spine fold page close sensor on the right was already ON when the spine fold plate was supposed to move from the open to the closed position.
  • Causes: • Spine fold motor: right (M29) defective • Spine fold close sensor: right (S69) defective • Sensor connector loose, broken, defective
  • Remedy:
  • Code: 796-9
  • Description: Dual Spine Plate Sensor Error: Right PB (D391) The spine fold HP sensor: right (S66) and spine fold close sensor: right (S69) turned ON at the same time.
  • Causes: • Spine fold HP sensor: right (S66) defective • Spine fold close sensor: right (S69) defective • Sensor connector loose, broken, defective
  • Remedy:
  • Code: 797-1
  • Description: Grip HP Sensor (S93) Error PB (D391) The grip HP sensor did not go OFF within the prescribed time because the main grip did not leave its home position. -or- The main grip unit did go ON because it did not arrive at the HP position after signature release.
  • Causes: • Book grip motor (M43) defective • Grip HP sensor (S93) defective • Sensor or motor harness loose, broken, defective
  • Remedy:
‹ First  < 67 68 69 70 71 72 73 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục