Description: Exposure Lamp Error (D016/D097 only) The standard white level was not detected properly when scanning the white plate.
Causes: • Exposure lamp defective • Lamp stabilizer defective • Exposure lamp connector defective • Scanner motor control unit (MCU board) defective • SBU board defective • Dirty standard white plate • Dirty scanner mirror or scanner mirror or lens block out of position
Description: Scanner Home Position Error 1 (D016/D097 only) The scanner home position sensor does not detect the OFF condition during initialization or copying
Causes: • Scanner home position sensor defective • Poor connection between HP sensor and MCU board • Scanner motor control unit (MCU board) defective • Scanner wire, timing belt, pulleys, or carriage out of position • Scanner motor defective • Poor connection or defective harness between MCU board and scanner motor
Description: Scanner Home Position Error 2 (D016/D097 only) Scanner home position sensor does not detect ON.
Causes: • Scanner home position sensor defective • Poor connection between MCU board and scanner home position sensor • Harness between MCU board and sensor defective • MCU board defective • Scanner wire, timing belt, pulleys, or carriage out of position • Scanner drive motor defective • Harness between MCU board and scanner motor disconnected
Description: Encoder Signal Error (D016/D097 only) The scanner motor encoder connector is not set correctly, or the encoder signal was not input.
Causes: • Scanner motor encoder connector disconnected • Scanner motor lead connector disconnected • Scanner motor defective • MCU board defective (scanner motor control unit) • Scanner wire, timing belt, pulleys, or carriage installation incorrect • Power supply connector disconnected (+38V ±24V) • Power supply unit (PSU-E board) defective
Description: Scanner Motor Error 1 (D016/D097 only) Scanner motor stopped before feedback from scanner HP sensor detected, or motor speed too slow when detected at scanner HP sensor.
Causes: • Scanner motor defective (high torque) • Overload on scanner drive mechanism • MCU board defective (scanner motor unit control)
Description: Scanner Motor Error 2 (D016/D097 only) The scanner motor does not stop within 15 mm after the scanner home position sensor turns on when the scanner returns.
Causes: • Scanner motor defective (low torque) • Overload on scanner drive mechanism • MCU board defective (scanner motor control unit)
Description: Scanner Motor Error 4 (D016/D097 only) The scanner motor speed does not reach the target speed by the time the scanning start point is reached.
Causes: • Scanner motor defective • Overload on scanner mechanism • PSU-Eb board defective • MCU board defective (scanner motor control unit)
Remedy:
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.