Code: 819

Description: Fatal kernel error Due to a control error, a RAM overflow occurred during system processing. One of the following messages was displayed on the operation panel.
Causes: • System program defective • Controller board defective • Optional board defective • Replace controller firmw
Remedy:

Code: 821

Description: Self-diagnostics error: ASIC [XXXX]: Detailed error code
Causes: [0B06] ASIC detection error The I/O ASIC for system control is not detected. • Defective ASIC • Defective North Bridge and PCI I/F
Remedy: Replace the controller board.

Code: 822

Description: Self-diagnostic error: HDD (Hard Disk Drive) [XXXX]: Detailed error code. [3003] Timeout error [3004] Command error When the main switch is turned on or starting the self-diagnostic, the HDD stays busy for the specified time or more.
Causes: • Loose connection • Defective HDD • Defective controller
Remedy: 1. Check that the HDD is correctly connected to the controller. 2. Replace the HDD. 3. Replace the controller.

Code: 824

Description: [1401] Self-diagnosis error: Standard NVRAM The controller cannot recognize the standard NVRAM installed or detects that the NVRAM is defective.
Causes: • Loose connection • Defective standard NVRAM • Defective controller
Remedy: 1. Check the standard NVRAM is firmly inserted into the socket. 2. Replace the NVRAM. 3. Replace the controller

Code: 829

Description: Self-diagnostic error 5: Optional RAM Verify error for optional RAM.
Causes: • Make sure that the resident RAM is installed in the correct slot. • Make sure the optional RAM is installed in the correct slot (Slot 0)
Remedy: 1. Install the optional RAM on the controller board. 2. Replace the controller board.

Code: 833

Description: Self-diagnostic error 8: Engine I/F ASIC
Causes: [0F30] [0F31] ASIC (Mandolin) for system control could not be detected. After the PCI configuration, the device ID for the ASIC could not be checked. • Replace the VBCU [0F41] ASIC (Mandolin) for system control could not be detected. After the PCI configuration, the device ID for the ASIC could not be checked. • Replace the VBCU [0F21] The machine detects an error from the resident RAM on the controller board at write/ verify check. Replace the controller board.
Remedy:

Code: 834

Description: Self-diagnostic error 9: Optional Memory RAM DIMM The write/verify check for the optional RAM chip on the controller board returned an error.
Causes: • Controller defective
Remedy: Replace the controller board.

Code: 851

Description: IEEE1394 interface error The 1394 interface is unusable.
Causes: • Defective IEEE1394 • Defective controller
Remedy: 1. Turn the main switch off and on. 2. Replace the IEEE1394 interface board. 3. Replace the controller.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie