Causes: This SC is issued if the error that the toner is not supplied is detected n times consecutively (n: SP2-931-005) on the condition that the toner cartridge is not in end • Overload on the toner transferring part (clogging of toner) • Screw for detecting PCDU does not turn • Detector element (sensor) defective: light leak • Supplying pick does not engage • Defective Supplying clutch • Defective Drive mechanism of screw for supplying toner cartridge
Causes: When the average value of the toner end sensor output count is 0 n times consecutively (n: SP2-931-003) • Connector contact failure/disconnected/broken • Detector element (sensor) does not emit light • Detecting surface inside the developing device is stained
Causes: • Temperature sensor output error: Out of range between 0.76 V and 2.90 V • Humidity sensor output error: 2.4 V or more • Unmounted sensor (Disconnected connector or broken wire) • Failed sensor
Remedy: • Turn the main power OFF and then ON. • Check that the connector is set. • Set the sensor. • Replace the sensor. • Replace the connector.
Causes: The signal from the by-pass bottom plate position sensor has not changed (the signal has not changed from ON to OFF or vice versa) for 4 seconds or more after the start of reverse Paper Feed Unit rotation, If the error is detected three times in succession, the SC number is displayed on the operation panel. • By-pass bottom plate sensor connector disconnected or other error • By-pass bottom plate sensor feeler stuck or other error
Remedy: • Check and replace the by-pass bottom plate sensor connector connection. • Replace the by-pass bottom plate sensor feeler. • Replace the Paper Feed Motor. • Replace the harness. • Replace the BCU.
Causes: When the main motor is driven, the lock (state of rotation) signal is checked every 100 milliseconds. If the machine detects the lock signal in the High status 20 times in succession, it reports this error. • The main motor incurs too much load from a defective unit. • The main motor is defective.
Remedy: • Replace the defective unit or the motor
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.