Mã lỗi Ricoh Aficio SPC811DN — Trang 3/23

Code: 230

Description: FGATE ON error: Bk
The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [K].
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the EGB. 2. Replace the EGB. 3. Replace the controller board.

Code: 231

Description: FGATE OFF error: Bk
• The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [K]. • The PFGATE ON signal still asserts when the next job starts.
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the EGB. 2. Replace the EGB. 3. Replace the controller board.

Code: 232

Description: FGATE ON error: Y
The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [Y].
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the EGB. 2. Replace the EGB. 3. Replace the controller board.

Code: 233

Description: FGATE OFF error: Y
• The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [Y]. • The PFGATE ON signal still asserts when the next job starts.
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the EGB. 2. Replace the EGB. 3. Replace the controller board.

Code: 234

Description: FGATE ON error: M
The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [M].
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the EGB. 2. Replace the EGB. 3. Replace the controller board.

Code: 235

Description: FGATE OFF error: M
• The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [M].
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the EGB. 2. Replace the EGB. 3. Replace the controller board.

Code: 236

Description: FGATE ON error: C
The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [C].
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the EGB. 2. Replace the EGB. 3. Replace the controller board.

Code: 237

Description: FGATE OFF error: C
• The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [C]. • The PFGATE ON signal still asserts when the next job starts.
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the EGB. 2. Replace the EGB. 3. Replace the controller board.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin