Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio SPC811DN — Trang 4/23

Code: 240

Description: LD error: Bk
The EGB detects LDB error a few times consecutively when LDB unit turns on after LDB initialization
Causes: • Worn-out LD • Disconnected or broken harness of the LD
Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the EGB.

Code: 241

Description: LD error: Y
The EGB detects LDB error a few times consecutively when LDB unit turns on after LDB initialization
Causes: • Worn-out LD • Disconnected or broken harness of the LD
Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the EGB.

Code: 242

Description: LD error: M
The EGB detects LDB error a few times consecutively when LDB unit turns on after LDB initialization
Causes: • Worn-out LD • Disconnected or broken harness of the LD
Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the EGB.

Code: 243

Description: LD error: C
The EGB detects LDB error a few times consecutively when LDB unit turns on after LDB initialization
Causes: • Worn-out LD • Disconnected or broken harness of the LD
Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the EGB.

Code: 285

Description: Line position adjustment (MUSIC) error
Line position adjustment fails four consecutive times.
Causes: • Pattern sampling error ( insufficient image density ) • Defective ID sensors for the line position adjustment • Defective image transfer belt unit • Defective PCU(s) • Defective laser optics housing unit
Remedy: 1. Check and reinstall the image transfer belt unit and PCUs. 2. Check if each toner bottle has enough toner. 3. Replace the ID sensor. 4. Replace the image transfer belt unit. 5. Replace the PCU(s). 6. Replace the laser optics housing unit.

Code: 290

Description: Shutter sensor time over error: Close
The shutter close sensor does not detect "ON" for 2000 msec after the shutter motor turns on
Causes: • Defective shutter close sensor • Disconnected or broken harness • Defective shutter motor • Defective shutter • Shutter motor overload • Defective IOB
Remedy: 1. Check or replace the harness. 2. Replace the shutter on the laser optics housing unit. 3. Replace the shutter motor. 4. Replace the shutter close sensor. 5. Replace the IOB.

Code: 291

Description: Shutter overrun error 1: Close
The shutter close sensor loses the "ON" signal after the shutter was closed.
Causes: • Defective motor • Change of load to shutter motor
Remedy: Replace the shutter on the laser optics housing unit.

Code: 292

Description: Shutter overrun error 2: Close
The shutter close sensor detects "ON" after SC 291 has occurred.
Causes: • Defective motor • Change of load to shutter motor
Remedy: Replace the shutter on the laser optics housing unit.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie