Code: 293

Description: Shutter sensor time over error: Open
The shutter open sensor does not detect "ON" for 2000 msec after the shutter motor turns on.
Causes: • Defective shutter close sensor • Disconnected or broken harness • Defective shutter motor • Defective shutter • Shutter motor overload • Defective IOB
Remedy: 1. Check or replace the harness. 2. Replace the shutter on the laser optics housing unit. 3. Replace the shutter motor. 4. Replace the shutter close sensor. 5. Replace the IOB.

Code: 294

Description: Shutter overrun error 1: Open
The shutter open sensor loses the "ON" signal after the shutter was closed.
Causes: • Defective motor • Change of load to shutter motor
Remedy: Replace the shutter on the laser optics housing unit.

Code: 295

Description: Shutter overrun error 2: Open
The shutter open sensor detects "ON" after SC 291 has occurred.
Causes: • Defective motor • Change of load to shutter motor
Remedy: Replace the shutter on the laser optics housing unit.

Code: 296

Description: Shutter open/close sensor error
Both shutter open sensor and close sensor detect "ON" at the same time.
Causes: • Broken harness(es) of the shutter open/close sensors
Remedy: Replace the shutter on the laser optics housing unit.

Code: 300

Description: AC charge output error [K]
The measured voltage is not proper when IOB measures the charge output for each color.
Causes: • Disconnected or broken high voltage cable • Defective or not installed PCU • Defective high voltage power supply
Remedy: 1. Check or replace the connectors. 2. Replace the PCU for the affected colour. 3. Replace the high voltage power supply.

Code: 301

Description: AC charge output error [M]
The measured voltage is not proper when IOB measures the charge output for each color.
Causes: • Disconnected or broken high voltage cable • Defective or not installed PCU • Defective high voltage power supply
Remedy: 1. Check or replace the connectors. 2. Replace the PCU for the affected colour. 3. Replace the high voltage power supply.

Code: 302

Description: AC charge output error [C]
The measured voltage is not proper when IOB measures the charge output for each color.
Causes: • Disconnected or broken high voltage cable • Defective or not installed PCU • Defective high voltage power supply
Remedy: 1. Check or replace the connectors. 2. Replace the PCU for the affected colour. 3. Replace the high voltage power supply.

Code: 303

Description: AC charge output error [Y]
The measured voltage is not proper when IOB measures the charge output for each color.
Causes: • Disconnected or broken high voltage cable • Defective or not installed PCU • Defective high voltage power supply
Remedy: 1. Check or replace the connectors. 2. Replace the PCU for the affected colour. 3. Replace the high voltage power supply.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie