Description: Line position adjustment (MUSIC) error
Line position adjustment fails three consecutive times.
Causes: • Pattern sampling error due to insufficient image density of patterns used for the adjustment • Inconsistency in the sampling line position adjustment pattern due to dust on the pattern, damage to the OPC drum, damage or toner dropped on the transfer belt, or a dirty or defective ID sensor
Code: 370
Description: TD sensor [K]: Adjustment error
During the developer initialization, the output value of the TD sensor is without the adjustment range (3.0 ± 0.1V).
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Code: 371
Description: TD sensor [Y]: Adjustment error
During the developer initialization, the output value of the TD sensor is without the adjustment range (3.0 ± 0.1V).
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Code: 372
Description: TD sensor [C]: Adjustment error
During the developer initialization, the output value of the TD sensor is without the adjustment range (3.0 ± 0.1V).
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Code: 373
Description: TD sensor [M] : Adjustment error
During the developer initialization, the output value of the TD sensor is without the adjustment range (3.0 ± 0.1V).
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Code: 374
Description: Vt error [K]
During the image development, Vt value is less than 0.5V.
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Code: 375
Description: Vt error [Y]
During the image development, Vt value is less than 0.5V.
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Code: 376
Description: Vt error [C]
During the image development, Vt value is less than 0.5V.
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor