Description: Transfer Output Error A high voltage feedback voltage of less than 0.5 V was detected for 200 ms.
Causes: • High voltage cable disconnected, damaged • T/S power pack defective
Remedy:
Code: 460
Description: DC Separation Corona Output Error A dc separation feedback voltage of less than 0.5 V was detected after more than 200 ms.
Causes: • High voltage cable disconnected, damaged • T/S power pack defective
Remedy:
Code: 508
Description: Cutter Error. The left and right cutter HP sensors remained on or off more than 2 sec.
Causes: HP sensors on the left and right side loose, disconnected, defective • Cutter motor harness damaged, defective • HP sensors defective • Cutter motor defective Note: Paper can be fed from the bypass table if the roll feeder or paper cassette is not operationg.
Remedy:
Code: 520
Description: Main Motor Error After the motor started, the main motor lock signal remained HIGH for 5 sec.
Causes: • Physical obstruction blocking motor • Motor harness damaged, defective • Motor defective
Remedy:
Code: 521
Description: Drum Motor Error After the motor started, the drum motor lock signal remained HIGH for 5 sec.
Causes: • Physical obstruction blocking motor • Motor harness damaged, defective • Motor defective
Remedy:
Code: 522
Description: Fusing Unit Drive Motor Error After the motor started, the fusing motor lock signal remained HIGH for 5 sec.
Causes: • Physical obstruction blocking motor • Motor harness damaged, defective • Motor defective
Remedy:
Code: 530
Description: Fusing Unit Ventilation Fan Error After the motor started, the fan motor lock signal remained HIGH for 5 sec.
Causes: • Physical obstruction blocking motor • Motor harness damaged, defective • Motor defective
Remedy:
Code: 541
Description: Fusing Thermistor Errors. The thermistor measured the hot roller temperature every 1 sec. for 30 sec. and the temperature remained below 5C (54F).