Description: Consecutive fusing jam The paper jam counter for the fusing unit reaches 3 times. The paper jam counter is cleared if the paper is fed correctly. This SC is activated only when SP1159-001 is set to "1" (default "0").
Causes: • Paper jam in the fusing unit.
Remedy: Remove the paper that is jammed in the fusing unit. Then make sure that the fusing unit is clean and has no obstacles in the paper feed path.
Code: 561
Description: Pressure roller thermistor error The temperature measured by the thermistor does not reach 0 °C for 37 seconds.
Causes: • Loose connection of the pressure roller thermistor • Defective pressure roller thermistor
Remedy: 1. Check if the pressure roller thermistor is firmly connected. 2. Replace the pressure roller thermistor.
Code: 562
Description: Pressure roller temperature error The temperature of the pressure roller does not reach the ready temperature for 120 seconds after the fusing lamp has turned on.
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the EGB.
Code: 564
Description: Pressure roller overheat 3 (hardware error) The thermistor detects 220°C or more.
Causes: • Defective PSU • Defective IOB • Defective EGB • Defective fusing control system
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the EGB.
Code: 565
Description: Pressure roller fusing lamp consecutive full power 3 When the fusing unit is not running in the ready condition, the pressure roller fusing lamp keeps ON full power for 180 seconds or more.
Causes: • Broken pressure roller fusing lamp
Remedy: 1. Replace the pressure roller lamp. 2. Replace the PSU.
Code: 580
Description: IH inverter zero cross frequency error The zero cross signal is not detected for 1 second or more after the IH inverter has turned on.
Causes: • Disconnected CN983 on the IH inverter • Defective IH inverter • Defective IH coil unit
Remedy: 1. Check CN983 on the IH inverter. 2. Replace the IH inverter. 3. Replace the IH coil unit.
Code: 581
Description: IH inverter input voltage error The IH inverter detects 70V or less/140V or more for 10 seconds.
Causes: • Unusual input voltage • Disconnected CN981 on the IH inverter • Defective IH inverter
Remedy: 1. Check CN981 on the IH inverter. 2. Replace the IH inverter.