Description: Zero cross error • The zero cross signal is detected three times even though the heater relay is off when turning on the main power. • The zero cross signal is not detected for 3 seconds even though the heater relay is on after turning on the main power or closing the front door. • The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected zero cross signal is less than 39.
Causes: • Defective fusing relay • Defective fusing relay circuit • Shorted +24V fuse on the PSU • Unstable power supply
Remedy: 1. Check the power supply source. 2. Replace the +24V fuse on the PSU. 3. Replace the PSU
Code: 548
Description: Fusing unit rotation error The fusing belt sensor does not detect change in the actuator for 0.5 seconds after the fusing/paper exit motor has turned on.
Causes: • Defective fusing/paper exit motor • Deformed actuator for the fusing belt sensor • Defective fusing belt sensor • Broken connection between IH inverter and IOB • Incorrectly set fusing unit
Remedy: 1. Check if the fusing unit is correctly set. 2. Check or replace the actuator for fusing belt sensor. 3. Replace the fusing belt sensor. 4. Replace the IH inverter. 5. Check the connection between IH inverter and IOB.
Code: 549
Description: Ferrite core rotation error The ferrite roller HP sensor does not detect the ferrite roller home position for 4 seconds after the fusing/paper exit motor has turned on.
Causes: • Deformed actuator for the ferrite roller HP sensor • Defective ferrite roller HP sensor • Defective ferrite roller motor • Shorted +24V fuse on the PSU • Defective IOB
Remedy: 1. Replace the heating roller. 2. Replace the ferrite roller HP sensor. 3. Replace the ferrite roller motor. 4. Replace the +24V fuse on the PSU. 5. Replace the IOB.
Code: 551
Description: Heating roller thermistor error The temperature measured by the heating roller thermistor does not reach 0 °C for 7 seconds.
Remedy: 1. Check that the heating roller thermistor is firmly connected. 2. Replace the heating roller thermistor.
Code: 552
Description: Heating roller warm-up error 2 • The heating roller temperature does not reach the ready temperature for 90 seconds after the heating lamp on. • The heating roller temperature does not reach 80°C for 13 seconds after the IH inverter on.
Causes: • Defective thermistor • Defective IH inverter
Remedy: 1. Check if the heating roller thermistor is firmly connected. 2. Replace the IH inverter.
Code: 553
Description: Heating roller overheat (software error) The detected heating roller temperature stays at 230°C or more for 1 second.
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the EGB.
Code: 554
Description: Heating roller overheat (hardware error) The heating roller thermistor detects 240°C or more.
Causes: • Defective PSU • Defective IOB • Defective EGB • Defective fusing control system
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the EGB.
Code: 557
Description: Zero cross frequency error When the zero cross signal is 66 or more and it is detected 10 times or more in 11 detections, the machine determines that input 60 Hz and SC557 occurs.