Description: Black drum motor error The LOCK signal error is detected when the EGB monitors the black drum motor state. (This monitoring is done immediately after power-on, when the motor starts rotating, and immediately after the motor stops.)
Causes: • Disconnected or defective motor harness. • Motor slips due to excessive load
Remedy: 1. Check the harness from the black drum motor. Replace it if necessary.
Code: 397
Description: Color drum motor error The LOCK signal error is detected when the EGB monitors the color drum motor state. (This monitoring is done immediately after power-on, when the motor starts rotating, and immediately after the motor stops.)
Causes: • Disconnected or defective motor harness. • Motor slips due to excessive load
Remedy: 1. Check the harness from the color drum motor. Replace it if necessary.
Code: 400
Description: Process Control Error This SC is issued if the process control adjustment fails 5 times consecutively after AIO replacement.
Causes: • Defective contact at the terminal between the machine and AIO. • Dirty TM sensor
Remedy: 1. Check the contact of the terminal and re-install the AIO. 2. Clean the TM sensor.
Code: 445
Description: ITB (Image Transfer Belt) Unit Error Home Position Error The ITB contact sensor does not detect the home position of the ITB for 5 seconds after the ITB unit initialization has been done. ITB (Image Transfer Belt) Unit: Contact Position Error The ITB contact sensor does not detect the contact position of the ITB for 5 seconds after the ITB unit has moved to the contact position. ITB (Image Transfer Belt) Unit: No-contact Position Error The ITB contact sensor does not detect the home position of the ITB for 5 seconds after the ITB unit has moved to no-contact position.
Causes: • Defective ITB contact motor • Defective ITB contact sensor • Defective ITB unit
Remedy: 1. Replace the ITB contact motor. 2. Replace the ITB contact sensor. 3. Replace the ITB unit.
Code: 480
Description: Agitator Motor Error The agitator motor error is detected twice for 10 msec during the initialization at power-on or after the cover is closed.
Causes: • Disconnected or defective harness. • Defective agitator motor
Remedy: 1. Check or replace the harness. 2. Replace the agitator motor.
Code: 490
Description: ITB (Image Transfer Belt) Unit Set Error The TM sensor does not detect the reflection from the ITB.
Causes: • No ITB unit in the machine • Dirty TM sensor
Remedy: 1. Check the installation of the ITB unit. 2. Clean the TM sensor.
Code: 500
Description: Main Motor Error The LOCK signal error is detected when the EGB monitors the main motor state. (This monitoring is done immediately after power-on, when the motor starts rotating, and immediately after the motor stops.)
Causes: • Disconnected or defective motor harness. • Motor slips due to excessive load
Remedy: 1. Check the harness from the main motor. Replace it if necessary.
Code: 530
Description: LSU Fan Motor Error A LOCK signal is not detected for more than ten seconds while the motor START signal is on and if this error occurs twice consecutively, this SC is issued.
Causes: • Disconnected or defective motor harness. • Defective LSU fan motor
Remedy: 1. Check or replace the motor harness. 2. Replace the LSU fan motor.