Description: Fusing thermistor error The fusing temperature remains lower than 0C for over 7 seconds after the power relay switches on.
Causes: Thermistor disconnected. Defective thermistor. Fusing unit connected improperlyor
Remedy: • Connect the fusing unit properly. • Connect the thermistor. • Replace the thermistor. • This SC cannot be reset by turning the power off and on. • This SP should be reset by a CE. • SP5810-01 can reset this SC.
Description: Fusing temperature warm-up error 1: Thermistor detects that the rate of heat increase is less than 7 degrees per 2 seconds consecutively 5 times. 2: The fusing temperature did not reach the standby temperature within 24 seconds at the center of the hot roller after the main switch turned on. This SC will appear when condition 1 and 2 occur at the same time.
Remedy: • Install the thermistor properly. • Replace the thermistor. • Replace the fusing lamp. • This SC cannot be reset by turning the power off and on. • This SP should be reset by a CE. • SP5810-01 can reset this SC.
Remedy: • Replace the Controller board. • This SC cannot be reset by turning the power off and on. • This SP should be reset by a CE. • SP5810-01 can reset this SC.
Remedy: • Replace the Controller board. • This SC cannot be reset by turning the power off and on. • This SP should be reset by a CE. • SP5810-01 can reset this SC.
Description: Fusing lamp remains on 1 The fusing lamps remained ON at full capacity for more than 12 seconds after the fusing temperature attains reload temperature.
Remedy: • Replace the fusing thermistor. • Replace the fusing lamp. • Replace the thermostat. • This SC cannot be reset by turning the power off and on. • This SP should be reset by a CE. • SP5810-01 can reset this SC.
Description: Zero cross signal detection error Zero cross signal is detected consecutively 4 times (for 200 ms) at power on with fusing relay being off. -or- Zero cross interrupts did not issue at the prescribed 3 second intervals. -or- The detection error occurs twice or more in 10 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45.
Causes: Defective fusing relay. Defective fusing relay circuit. Shorted +24V fuse on the PSU. Unstable AC power. AC line noise. As for an error due to a high frequency noise interference, this SC will not appear. In this case, SC557 will appear and output the log only.
Remedy: • Turn the Power Switch Off and On. • Replace the PSU.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.