Description: Stack height lever solenoid error Stack height lever sensor does not turn on when the stack height lever solenoid turns off. • Paper jam message is displayed at 1st error detection. • SC is issued at 2nd error detection.
Causes: • Loose connection of the stack height lever solenoid • Defective stack height lever solenoid • Defective stack height lever sensor
Causes: The boot loader cannot read one of the following: Self-diagnostic module, kernel, or one of the files of the root file system, or the check of one of these items on the controller board failed.
Remedy: • File or module on the controller board is corrupted. • File or module on the controller board is illegal. • Replace the controller board
Causes: [0F30] [0F31] ASIC (Mandolin) for system control could not be detected. After the PCI configuration, the device ID for the ASIC could not be checked. Replace the BICU. [0F41] ASIC (Mandolin) for system control could not be detected. After the PCI configuration, the device ID for the ASIC could not be checked. Replace the BICU. [50B1] Could not initialize or read the bus connection. Check for loose connections at the mother board. Replace the BICU. [50B2] Value of the SSCG register is incorrect. Check for loose connections at the mother board. Replace the BICU.
Description: Flash ROM verification error Verification error of the flash ROM on the controller board occurs. • This SC is logged at 1st error detection. • SC819 is issued at 2nd error detection.