Remedy: 1. Check the connection between the controller and the engine board. 2. Replace the engine board if the error is frequent. 3. Replace the controller board if the error is frequent.
Code: 652
Description: Remote Service ID2 Mismatch Error 1 ID2 for the device did not match the ID2 stored in NVRAM. This error can occur if the controller has been replaced with the Cumin ID2 set for another machine, or if the NVRAM has been replaced with the NVRAM from another machine.
Causes: • If this error occurs when Cumin is set up, check the Cumin documentation and make sure that the NVRAM is compatible, set the common authentication, then try again. • If this error occurs after Cumin has been set, clear the Cumin setting, check the Cumin documentation and make sure that the NVRAM is compatible, set the common authentication, then try again.
Remedy:
Code: 653
Description: Remote Service ID2 Mismatch Error 2 One of the following problems exist with the ID2 stored in NVRAM: • ID2 has less than 17 digits • A non-printable character exists in ID2 • ID2 is all spaces • ID2 is NULL
Causes: 1. Replace NVRAM. 2. Clear the Cumin setting, set the common authentication, then try again.
Remedy: 1. Replace NVRAM. 2. Clear the Cumin setting, set the common authentication, then try again.
Code: 669
Description: EEPROM Error An unexpected value exists in the initialization flag of the EEPROM.
Causes: EEPROM not initialized. Defective EEPROM.
Remedy: 1. Initialize the EEPROM. 2. Replace the EEPROM. 3. Replace the EGB.
Code: 670
Description: Engine startup error The EGB fails to respond within the prescribed time when the machine is turned on.
Causes: • Connections between EGB and controller board are loose, disconnected, or damaged • EGB defective • Controller board defective
Remedy: 1. Check the type of EGB and controller board. 2. Replace the EGB. 3. Replace the controller board.
Code: 690
Description: GAVD Communication Error The ID of the GAVD is not identified during initialization.
Causes: Defective EGB
Remedy: 1. Replace the EGB.
Code: 816
Description: Energy save I/O subsystem error An error was detected in the signal from the ASIC (controller board) which controls the STR (Suspend to RAM) function. Note: STR is a feature of this machine that minimizes energy consumption while the machine is in the energy saver mode.
Causes: -5 SCS • Reboot the machine. • Replace the controller board. -39 Sub System Error occurred during system start up. -50 Hardware Printer version only. Not used for this machine. -67 NCS (Network Control Service) An error occurred in the access control port list: • Number of registrations exceeded 125 • Data notifications exceeded 12 • Data extension incorrect -79 Sub System Message mismatch. -90 Hardware/System A forced system reset (WDOG) occurred.