Description: Pressure roller thermistor error: Center The center temperature of the pressure roller measured by the thermistor does not reach 0°C for 8 seconds.
Description: Pressure roller thermistor warm-up error: Center The center temperature of the pressure roller measured by the thermistor does not reach 41°C within 8 seconds after the heater turns on.
Description: Pressure roller overheat : Center (software error) The detected pressure roller temperature stays at 230°C or more for 1 second for 10 consecutive times.
Causes: The triac has shorted out. Defective IOB. Defective BCU.
Remedy:
Code: 574
Description: Pressure roller overheat : Center (hardware error) The thermistor detects 240°C or more.
Remedy: • Replace the PSU. • Replace the BCU. • Replace the IOB. • Replace the fusing unit and reset the counter of the fusing unit using SP3-902-014. Important: The fusing unit cannot be used because an abnormal high temperature was detected. • After this SC occurs, the counter reset of the fusing unit should be done manually using SP3-902-014 because the counter reset is not done automatically. • After replacing fusing unit, to set SP5-810-2 is necessary to reset this SC.
Code: 581
Description: NC sensor broken: Center The sensor detects -17°C or less for 6 seconds