Các lỗi thường gặp

Code :
  • Code: 569-01
  • Description: Fusing shutter sensor error
    Fusing shutter plate home position sensor error is detected three consecutive times.
  • Causes: Defective fusing shutter plate. Defective photo interrupter. Defective connectors.
  • Remedy:
  • Code: 571
  • Description: Pressure roller thermistor error: Center
    The center temperature of the pressure roller measured by the thermistor does not reach 0°C for 8 seconds.
  • Causes: Defective thermopile. Defective thermistor. Loose connection.
  • Remedy:
  • Code: 572-02
  • Description: Pressure roller thermistor warm-up error: Center
    The center temperature of the pressure roller measured by the thermistor does not reach 41°C within 8 seconds after the heater turns on.
  • Causes: Dirty thermopile lenses. Deformed thermistor.
  • Remedy:
  • Code: 573
  • Description: Pressure roller overheat : Center (software error)
    The detected pressure roller temperature stays at 230°C or more for 1 second for 10 consecutive times.
  • Causes: The triac has shorted out. Defective IOB. Defective BCU.
  • Remedy:
  • Code: 574
  • Description: Pressure roller overheat : Center (hardware error)
    The thermistor detects 240°C or more.
  • Causes: Defective PSU. Defective BCU. Defective IOB. Defective fusing control system.
  • Remedy: • Replace the PSU. • Replace the BCU. • Replace the IOB. • Replace the fusing unit and reset the counter of the fusing unit using SP3-902-014. Important: The fusing unit cannot be used because an abnormal high temperature was detected. • After this SC occurs, the counter reset of the fusing unit should be done manually using SP3-902-014 because the counter reset is not done automatically. • After replacing fusing unit, to set SP5-810-2 is necessary to reset this SC.
  • Code: 581
  • Description: NC sensor broken: Center
    The sensor detects -17°C or less for 6 seconds
  • Causes: Defective thermopile. Defective thermistor. Loose connection.
  • Remedy:
  • Code: 591
  • Description: NC sensor broken: End
    The sensor detects -17°C or less for 6 seconds.
  • Causes: Broken cables of thermopile. Broken cables of thermistor. Loose connection.
  • Remedy:
  • Code: 621
  • Description: Finisher/Mail box communication error
    An error occurs during line connection. A communication error report is received from the UART.
  • Causes: The finisher's control board is faulty. Defective BCU/IOB. The finisher's connection is faulty. Reconnect the finisher/mail box cables.
  • Remedy: • Reconnect the finisher/mail box cables. • Replace the BCU. • Replace the finisher/mail box. • Turn the main power switch off and on.