Description: Laser synchronizing detection error: start position [K]: LD1 The laser synchronizing detection signal for the start position of the LDB [K], [C], [M], [Y] is not output for 600 ms after LDB unit turned on while the polygon motor is rotating normally.
Causes: Disconnected or defective I/F harness to laser synchronizing detection unit. Defective laser synchronizing detection unit. The laser fails to reach the photo detector. Defective GAVD. Defective LD board or driver. Defective BCU.
Remedy: • Turn the main power switch off and on. • Replace the laser optics housing unit. • Replace the I/F harness. • Replace the BCU.
Description: Laser synchronizing detection error: start position [C]: LD1 The laser synchronizing detection signal for the start position of the LDB [K], [C], [M], [Y] is not output for 600 ms after LDB unit turned on while the polygon motor is rotating normally.
Causes: Disconnected or defective I/F harness to laser synchronizing detection unit. Defective laser synchronizing detection unit. The laser fails to reach the photo detector. Defective GAVD. Defective LD board or driver. Defective BCU.
Remedy: • Turn the main power switch off and on. • Replace the laser optics housing unit. • Replace the I/F harness. • Replace the BCU.
Description: Laser synchronizing detection error: start position [M]: LD1 The laser synchronizing detection signal for the start position of the LDB [K], [C], [M], [Y] is not output for 600 ms after LDB unit turned on while the polygon motor is rotating normally.
Causes: Disconnected or defective I/F harness to laser synchronizing detection unit. Defective laser synchronizing detection unit. The laser fails to reach the photo detector. Defective GAVD. Defective LD board or driver. Defective BCU.
Remedy: • Turn the main power switch off and on. • Replace the laser optics housing unit. • Replace the I/F harness. • Replace the BCU.
Description: Laser synchronizing detection error: start position [Y]: LD1 The laser synchronizing detection signal for the start position of the LDB [K], [C], [M], [Y] is not output for 600 ms after LDB unit turned on while the polygon motor is rotating normally.
Causes: Disconnected or defective I/F harness to laser synchronizing detection unit. Defective laser synchronizing detection unit. The laser fails to reach the photo detector. Defective GAVD. Defective LD board or driver. Defective BCU.
Remedy: • Turn the main power switch off and on. • Replace the laser optics housing unit. • Replace the I/F harness. • Replace the BCU.
Description: Laser synchronizing detection error: start position [K]: LD2 The laser synchronizing detection signal for the start position of the LDB [K], [C], [M], [Y] is not output for 600 ms after LDB unit turns on while the polygon motor is rotating normally.
Causes: The laser fails to reach the photo detector. Defective GAVD. Defective LD driver. Defective LDB. Defective BCU.
Remedy: • Turn the main power switch off and on. • Replace the laser optics housing unit. • Replace the BCU.
Description: Laser synchronizing detection error: start position [C]: LD2 The laser synchronizing detection signal for the start position of the LDB [K], [C], [M], [Y] is not output for 600 ms after LDB unit turns on while the polygon motor is rotating normally.
Causes: The laser fails to reach the photo detector. Defective GAVD. Defective LD driver. Defective LDB. Defective BCU.
Remedy: • Turn the main power switch off and on. • Replace the laser optics housing unit. • Replace the BCU.
Description: Laser synchronizing detection error: start position [M]: LD2 The laser synchronizing detection signal for the start position of the LDB [K], [C], [M], [Y] is not output for 600 ms after LDB unit turns on while the polygon motor is rotating normally.
Causes: The laser fails to reach the photo detector. Defective GAVD. Defective LD driver. Defective LDB. Defective BCU.
Remedy: • Turn the main power switch off and on. • Replace the laser optics housing unit. • Replace the BCU.
Description: Laser synchronizing detection error: start position [Y]: LD2 The laser synchronizing detection signal for the start position of the LDB [K], [C], [M], [Y] is not output for 600 ms after LDB unit turns on while the polygon motor is rotating normally.
Causes: The laser fails to reach the photo detector. Defective GAVD. Defective LD driver. Defective LDB. Defective BCU.
Remedy: • Turn the main power switch off and on. • Replace the laser optics housing unit. • Replace the BCU.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.