Description: Charge P.P. output error: M The feedback voltage of the charge AC for each color is 0.3 V or less for 200 ms after the charge AC has been turned on.
Causes: Disconnected or broken harnesses of the HVPS. Disconnected or broken PCU. Defective HVPS (C/B). Loose connection. Broken harness.
Remedy: • Reinstall or replace the harnesses of the HVPS. • Reinstall or replace the PCU. • Replace the HVPS (C/B). • Reconnect the connector.
Code: 312-04
Description: Charge P.P. output error: Y The feedback voltage of the charge AC for each color is 0.3 V or less for 200 ms after the charge AC has been turned on.
Causes: Disconnected or broken harnesses of the HVPS. Disconnected or broken PCU. Defective HVPS (C/B). Loose connection. Broken harness.
Remedy: • Reinstall or replace the harnesses of the HVPS. • Reinstall or replace the PCU. • Replace the HVPS (C/B). • Reconnect the connector.
Code: 360-01
Description: TD sensor adjustment error: K During TD sensor initialization, the output value of the black, cyan, magenta, or yellow TD sensor is not within the range of the specified value with SP3-238-001 to -004 (default: 2.5V)+-0.2V
Causes: A TD sensor-related part is faulty. A TD sensor-related part's connection is loose. The developer's toner thickness differs from that of the initial developer.
Remedy: • Turn the main power switch off and then back on. • Replace the PCU.
Code: 360-02
Description: TD sensor adjustment error: C During TD sensor initialization, the output value of the black, cyan, magenta, or yellow TD sensor is not within the range of the specified value with SP3-238-001 to -004 (default: 2.5V)+-0.2V
Causes: A TD sensor-related part is faulty. A TD sensor-related part's connection is loose. The developer's toner thickness differs from that of the initial developer.
Remedy: • Turn the main power switch off and then back on. • Replace the PCU.
Code: 360-03
Description: TD sensor adjustment error: M During TD sensor initialization, the output value of the black, cyan, magenta, or yellow TD sensor is not within the range of the specified value with SP3-238-001 to -004 (default: 2.5V)+-0.2V
Causes: A TD sensor-related part is faulty. A TD sensor-related part's connection is loose. The developer's toner thickness differs from that of the initial developer.
Remedy: • Turn the main power switch off and then back on. • Replace the PCU.
Code: 360-04
Description: TD sensor adjustment error: Y During TD sensor initialization, the output value of the black, cyan, magenta, or yellow TD sensor is not within the range of the specified value with SP3-238-001 to -004 (default: 2.5V)+-0.2V
Causes: A TD sensor-related part is faulty. A TD sensor-related part's connection is loose. The developer's toner thickness differs from that of the initial developer.
Remedy: • Turn the main power switch off and then back on. • Replace the PCU.
Code: 361-01
Description: TD sensor (Vt high) error 1: K The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3-020-002 for twenty counts. The [Vt - Vtref] value of the black, cyan, magenta, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3-020-001.
Causes: A TD sensor-related part is faulty. A TD sensor-related part's connection is loose. Toner density error.
Remedy: • Turn the main power switch off and then back on. • Replace the AIT (development unit).
Code: 361-02
Description: TD sensor (Vt high) error 1: C The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3-020-002 for twenty counts. The [Vt - Vtref] value of the black, cyan, magenta, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3-020-001.
Causes: A TD sensor-related part is faulty. A TD sensor-related part's connection is loose. Toner density error.
Remedy: • Turn the main power switch off and then back on. • Replace the AIT (development unit).