Description: HC Control PCB communication error (timeout error) A command from the HC Control PCB was not received during the HC Control-MC communication within the specified interval.
Code: 045 S95
Description: Download error (HC Control PCB detection) An error was detected on the HC Control PCB side during a download.
Code: 046 S95
Description: Download error (IP PCB detection) An error was detected on the IP PCB side during a download.
Code: 047 S95
Description: Download error (MC PCB detection) An error was detected on the MC PCB side during a download.
Code: 048 S99
Description: FRAM checksum error FRAM checksum error of the HC Control PCB
Code: 049 S99
Description: FRAM read verify error The data does not match data read from the FRAM of the HC Control PCB.
Code: 050 S99
Description: FRAM write verify error The data does not match data written to the FRAM of the HC Control PCB.
Code: 051 M03
Description: Operation in temporary registration status The main unit is currently operating under temporary registration.