Description: Auto fence communication error A Test mode status command was not received before the elapse of the specified interval after the transmission of the Test mode execution command.
Code: 037 S99
Description: Multi-tray paper feed communication error 2 Multi-tray paper feed communication transmission error
Code: 038 S99
Description: Multi-tray paper feed communication error 3 Multi-tray paper feed communication reception break error
Code: 039 S99
Description: Multi-tray paper feed communication error 4 Multi-tray paper feed communication transmission buffer error
Code: 040 S98
Description: R/W PCB failure 1 Initial communication with the R/W PCB failed.
Code: 041 S98
Description: R/W PCB failure 2 Run signal timeout
Code: 042 S96
Description: R/W PCB failure 3 Connection signal timeout (The PCB is not connected.)
Code: 043 S96
Description: HC Control PCB not connected The connection of the HC Control PCB cannot be confirmed. (The HC Control PCB READY signal cannot be confirmed when the IP PCB is powered on.)