Code :
  • Code: 100 S12
  • Description: Exit motor encoder error The encoder frequency input from the exit motor unit deviates from the theoretical value.
  • Code: 101 S98
  • Description: Multiple feed sensor error A change in light intensity does not change the amount of light received at power ON or during initialization to reset a multiple feed error. * This error can be cleared by the panel setting [Multiple feed detection OFF].
  • Code: 102 S12
  • Description: Wing motor timeout The wings do not reach the HP when they are operated for a period of time corresponding to the distance of travel.
  • Code: 103 S12
  • Description: Wing motor timeout The wing HP sensor does not detect the movement of the wings from the HP when they are operated for the specified interval.
  • Code: 104 S02
  • Description: Elevator motor timeout The upper limit sensor fails to activate when the elevator rising operation is activated within the specified interval.
  • Code: 105 X14
  • Description: Standard paper feed tray multiple feed A multiple feed was detected during transport of paper from the standard paper feed tray.
  • Code: 106 X01
  • Description: Standard paper feed tray feed failure (no paper transport) The registration sensor fails to activate when the specified number of clock inputs is issued from the belt encoder after paper transport from the standard paper feed tray begins
  • Code: 107 X03
  • Description: Exit sensor paper end exiting delay The trailing edge of the paper sheet does not pass the exit sensor (sensor detecting the presence of paper) within the specified interval based on the belt encoder pulse count.