Description: Transfer belt motor timeout The motor shaft encoder of the transfer belt motor does not attain the specified pulse count within the specified time. The required movement does not complete even when the transfer belt motor operates for the specified interval.
Code: 201 S03
Description: Transfer belt unit sensor error The three sensors that determine the position of the belt platen produced an abnormal detection result.
Code: 202 S01
Description: Transfer belt motor error An alarm signal from the DC servo motor was detected (detection of overcurrent during operations).
Code: 203 S01
Description: Transfer belt motion speed error The clock frequency of the belt motor shaft encoder falls outside the specified range.
Code: 204 S01
Description: Belt encoder error The frequency input from the belt encoder is below the specified value.
Code: 205 S96
Description: Blower fan 1 disconnected/not connected The connector for blower fan 1 is disconnected, or there is a break in the winding.
Code: 206 S96
Description: Blower fan 2 disconnected/not connected The connector for blower fan 2 is disconnected, or there is a break in the winding.
Code: 207 S96
Description: Blower fan 3 disconnected/not connected The connector for blower fan 3 is disconnected, or there is a break in the winding.