Description: Side Regi. SNR OFF fail
•Side Regi. SNR does not turn OFF within 500 msec of start of operation.
•Side Regi. SNR does not turn OFF after operation termination following Side Regi. SNR OFF.
Code: 601 U04
Description: Compile Stacker Tray offset fail
•Stacker Front Position SNR does not turn ON within 500 msec of start of operation.
•Stacker Front Position N SNR does not turn ON within 500 msec of start of operation.
Code: 602 U04
Description: Tamper Home SNR OFF fail
•Tamper Home SNR does not turn OFF after operation termination following Tamper Home SNR OFF.
Code: 603 U04
Description: Tamper Home SNR ON fail
•Tamper Home SNR does not turn ON within 800 msec of start of operation.
Code: 604 U04
Description: End Wall Home SNR OFF fail
•End Wall Home SNR does not turn OFF within 100 msec of start of operation.
Code: 605 U04
Description: End Wall Open SNR ON fail
•End Wall Open SNR does not turn ON within 300 msec of start of operation.
Code: 606 U04
Description: End Wall Home SNR ON fail
•End Wall Home SNR does not turn ON within 300 msec of start of operation.
Code: 607 U04
Description: End Wall Open SNR OFF fail
•End Wall Open SNR does not turn OFF within 100 msec of start of operation.