Description: Eject Clamp Up SNR OFF fail
•Eject Clamp Up SNR does not turn OFF within 300 msec of start of operation.
•Eject Clamp Up SNR does not turn OFF after operation termination following Eject Clamp Up SNR OFF.
Code: 609 U04
Description: Eject Clamp Up SNR ON fail
•Eject Clamp Up SNR does not turn ON within 300 msec of start of operation.
•Eject Clamp Up SNR does not turn ON after operation termination following Eject Clamp Up SNR ON.
Code: 610 U04
Description: Shelf Home SNR OFF fail
•Shelf Home SNR does not turn OFF within 300 msec of start of operation.
•Shelf Home SNR does not turn OFF after operation termination following Shelf Home SNR OFF.
Code: 611 U04
Description: Shelf Home SNR ON fail
•Shelf Home SNR does not turn ON within 300 msec of start of operation.
•Shelf Home SNR does not turn ON after operation termination following Shelf Home SNR ON.
Code: 612 U04
Description: Stapler fail
•Stable Home SNR OFF > ON not detected within 450 msec of forward operation startup. Stapler Head Home SNR does not turn ON at least once within 200 msec of Staple Mot reverse rotation.
Code: 613 U04
Description: Staple Move Home SNR OFF fail
•Staple Move Home SNR does not turn OFF within 150 msec of start of operation.
•Staple Move Home SNR does not turn OFF after operation termination following Staple Move Home SNR OFF.
Code: 614 U04
Description: Staple Move Home SNR ON fail
•Staple Move Home SNR does not turn ON within 3000 msec of start of operation.
•Staple Move Home SNR does not turn ON after operation termination following Staple Move Home SNR ON.
Code: 615 U04
Description: Staple Center Position SNR ON fail
•Staple Center Position SNR does not turn ON within 3000 (200*) msec of start of operation.
•Staple Center Position SNR does not turn ON after operation termination following Staple Center Position SNR ON.