Description: Staple Center Position SNR OFF fail
•Staple Center Position SNR does not turn OFF within 150 msec of start of operation.
•Staple Center Position SNR does not turn OFF after operation termination following Staple Center Position SNR OFF.
Code: 617 U04
Description: Sub Paddle Home SNR ON fail
•Sub Paddle Home SNR does not turn ON within 800 msec of detection of Sub Paddle Home SNR OFF.
Code: 618 U04
Description: Sub Paddle Home SNR OFF fail
•Sub Paddle Home SNR does not turn ON within 3000 msec of start of operation.
Code: 619 U05
Description: Interposer Tray up fail
•Level Down SNR does not turn OFF within TBD msec of the start of the Interposer Tray U/D MOT lifting operation.
Code: 620 U06
Description: End Guide MOT1 start fail
•End Guide Home SNR1 does not turn OFF within 40 msec of End Guide MOT1 start operation following movement of the End Guide1 from the home position.
Code: 621 U06
Description: End Guide MOT2 start fail
•End Guide Home SNR2 does not turn OFF within 40 msec of End Guide MOT2 start operation following movement of the End Guide2 from the home position.
Code: 622 U06
Description: End Guide MOT1 home fail
•End Guide Home SNR1 does not turn ON within TBD msec of End Guide MOT1 start operation following movement of the End Guide1 from the home position.
Code: 623 U06
Description: End Guide MOT2 home fail
•End Guide Home SNR2 does not turn ON within TBD msec of End Guide MOT2 start operation following movement of the End Guide2 from the home position.