Mã lỗi Roland CT304

Code: -

Display: OFF-SCALE
Description: Data sent has exceeded the effective area.

Code: -

Display: DATA RECEIVED DURING COPYING!
Description: Another data is received during the execution of copying.

Code: 00

Display: ERROR 00 MAIN ROM
Description: Hash check error has arisen on the main ROM.

Code: 02

Display: ERROR 02 MAIN RAM
Description: Read/write error has arisen on the main RAM.

Code: 04

Display: ERROR 04 EEPROM
Description: Hash check error has arisen on the EEPROM. (Hash check is performed for the system parameter area.)

Code: 06

Display: ERROR 06 BUFFER
Description: Receiving buffer is in abnormal conditions.

Code: 08

Display: ERROR 08 POWER
Description: Supply voltage for driving the motor is abnormal.

Code: 10

Display: ERROR 10 COMMAND
Description: Unbreakable command code is received