Description: An erroneous operation has been taken (such that SELF TEST is executed while the device is engaged in self test or COPY is executed while the device is engaged in copying).
Code: 31
Display: ERROR 31 NO DATA
Description: No data is present in the receiving buffer though 'COPY' operation is executed.
Code: 32
Display: ERROR 32 TOO LARGE
Description: COPY has been executed after receiving data of which amount exceeds the capacity of the receiving buffer.
Code: 40
Display: ERROR 40 X OVERLOAD
Description: Load applied to servo-motor X has increased to an abnormal level.
Code: 41
Display: ERROR 41 Y OVERLOAD
Description: Load applied to servo-motor Y has increased to an abnormal level.
Code: 42
Display: ERROR 42 X OVERCURRENT
Description: Overcurrent error of servo-motor X has been detected. (The mean current exceeds the rated current of the motor.)
Code: 43
Display: ERROR 43 Y OVERCURRENT
Description: Overcurrent error of servo-motor Y has been detected. (The mean current exceeds the rated current of the motor.)
Code: 46
Display: ERROR 46 PEN SENSOR
Description: FPC circuit board is improperly positioned. Head circuit board is defective. CPU circuit board is defective